AI Chat Paper
Note: Please note that the following content is generated by AMiner AI. SciOpen does not take any responsibility related to this content.
{{lang === 'zh_CN' ? '文章概述' : 'Summary'}}
{{lang === 'en_US' ? '中' : 'Eng'}}
Chat more with AI
PDF (10.6 MB)
Collect
Submit Manuscript AI Chat Paper
Show Outline
Outline
Show full outline
Hide outline
Outline
Show full outline
Hide outline
Research Article | Open Access | Just Accepted

Disentangling genuine biomarker responses from oxygen-mediated backgrounds in photoactivated conductive MOF thin films

Xiumei Wu1,2,§, Jiahui Guo1,2,§, Xingyu Liu1, Sai Chu1,2, Xiuyan Qiu1, Xinyao Jiang1, Yongbin Yao1, Xi Wang3, Fangli Yuan1,2, Ming-Shui Yao1,2( )

1 State Key Laboratory of Mesoscience and Process Engineering, Institute of Process Engineering, Chinese Academy of Sciences, Beijing 100190, China

2 School of Chemical Engineering, University of Chinese Academy of Sciences, Beijing 100049, China

3 Key Laboratory of Luminescence and Optical Information, Ministry of Education, School of Physical Science and Engineering, Beijing Jiaotong University, Beijing 100044, China

§ Xiumei Wu and Jiahui Guo contributed equally to this work.

Show Author Information

Abstract

Conductive metal–organic frameworks (cMOFs) are promising materials for room-temperature gas sensing; however, the interplay among photoactivation, ambient oxygen, and target-gas adsorption remains poorly understood. Here, we report nanoscale conductive Cu-HHTT thin films fabricated via a layer-by-layer assembly approach and systematically investigate their sensing behavior toward 3-hydroxy-2-butanone (3H2B). Under 365 nm illumination, the films exhibit only a weak electrical response to 3 ppm 3H2B in a stable air background, while achieving an experimentally determined detection limit of 30 ppb. In contrast, switching between air and N2 produces a substantially larger electrical response. Further analysis reveals a pronounced atmosphere-dependent background contribution to the photoinduced electrical signal, which can complicate the accurate identification of the genuine gas response. This work establishes an evaluation strategy for distinguishing genuine VOC responses from oxygen-mediated background signals, providing a useful framework for performance assessment and mechanistic understanding of photoactivated cMOFs gas sensors.

Graphical Abstract

References

【1】
【1】
 
 
Nano Research

{{item.num}}

Comments on this article

Go to comment

< Back to all reports

Review Status: {{reviewData.commendedNum}} Commended , {{reviewData.revisionRequiredNum}} Revision Required , {{reviewData.notCommendedNum}} Not Commended Under Peer Review

Review Comment

Close
Close
Cite this article:
Wu X, Guo J, Liu X, et al. Disentangling genuine biomarker responses from oxygen-mediated backgrounds in photoactivated conductive MOF thin films. Nano Research, 2026, https://doi.org/10.26599/NR.2026.94909229

45

Views

10

Downloads

0

Crossref

0

Web of Science

0

Scopus

0

CSCD

Received: 07 September 2026
Revised: 22 September 2026
Accepted: 28 September 2026
Available online: 28 September 2026

© The Author(s) 2026. Published by Tsinghua University Press.

This is an open access article under the terms of the Creative Commons Attribution 4.0 International License (CC BY 4.0, https://creativecommons.org/licenses/by/4.0/)