Research Article | Open Access

A portable platform for renal function monitoring: Simultaneous quantification of creatinine and uric acid using a smartphone-coupled photonic crystal sensor

Rui Li1, Li Zhang2, Yang Lu1, Ting Liu1, Yuhan Yang1, Yuyao Hong1, Xiaomin Liu1 ( ), Geyu Lu1
State Key Laboratory on Integrated Optoelectronics, Key Laboratory of Advanced Gas Sensors of Jilin Province, College of Electronic Science & Engineering, Jilin University, Changchun 130012, China
Department of Pulmonology, Children’s Medical Center, The First Hospital of Jilin University, Changchun 130021, China
Show Author Information

Abstract

Given the intricate pathophysiological interplay between renal dysfunction and metabolic disorders, the multiplexed detection of creatinine and uric acid is indispensable for the holistic risk stratification and management of chronic kidney disease (CKD). To tackle poor signal-to-noise ratios at trace analyte concentrations, we developed a photonic crystal (PC)-based sensing chip for the simultaneous detection of creatinine and uric acid, utilizing NaYF4:Yb,Er@NaYF4 and NaErF4:Tm@NaYF4 upconversion nanoprobes. Notably, the integration of the PC led to 5.9-fold and 3.8-fold enhancement in the detection sensitivity for creatinine and uric acid, respectively. This improvement is attributed to the efficient signal amplification derived from the Bragg mirror reflection effect inherent to the PC structure. The chip exhibited excellent stability and accuracy in complex biological matrices, including serum and whole blood, with relative deviations from clinical standards of less than 4.1% and 2.0%, respectively. By integrating the chip with a smartphone application, we established a portable analysis system that automatically captures and processes fluorescence images to provide visual and quantitative readouts. This work proposes a generic strategy for amplifying fluorescence-based biosensing technology, offering a powerful tool for the rapid and low-cost diagnosis of CKD and paving the way for next-generation high-performance point-of-care testing platforms.

Graphical Abstract

To overcome poor signal-to-noise ratios in trace analyte detection critical for chronic kidney disease (CKD) risk stratification, a photonic crystal (PC)-based sensing chip was developed for simultaneous multiplexed detection of creatinine and uric acid using NaYF4:Yb,Er@NaYF4 and NaErF4:Tm@NaYF4 upconversion nanoprobes, achieving 5.9-fold and 3.8-fold sensitivity enhancements via the PC’s Bragg mirror reflection effect. The chip demonstrated excellent stability/accuracy in serum and whole blood (relative deviations < 4.1% and < 2.0% from clinical standards), integrated with a smartphone app for automated fluorescence imaging and visual quantification, thereby offering a rapid and low-cost CKD diagnostic tool and advancing high-performance point-of-care testing through a generic fluorescence amplification strate.

Electronic Supplementary Material

Download File(s)
8767_ESM.pdf (1.8 MB)

References

【1】
【1】
 
 
Nano Research
Article number: 94908767

{{item.num}}

Comments on this article

Go to comment

< Back to all reports

Review Status: {{reviewData.commendedNum}} Commended , {{reviewData.revisionRequiredNum}} Revision Required , {{reviewData.notCommendedNum}} Not Commended Under Peer Review

Review Comment

Close
Close
Cite this article:
Li R, Zhang L, Lu Y, et al. A portable platform for renal function monitoring: Simultaneous quantification of creatinine and uric acid using a smartphone-coupled photonic crystal sensor. Nano Research, 2027, 20(1): 94908767. https://doi.org/10.26599/NR.2026.94908767

643

Views

50

Downloads

0

Crossref

0

Web of Science

0

Scopus

0

CSCD

Received: 10 March 2026
Revised: 14 April 2026
Accepted: 21 April 2026
Published: 26 June 2026
© The Author(s) 2027. Published by Tsinghua University Press.

This is an open access article under the terms of the Creative Commons Attribution 4.0 International License (CC BY 4.0, https://creativecommons.org/licenses/by/4.0/).