3D Dynamic Contrast-Enhanced Ultrasound for Personalized RRx-001 Dosing: A Preclinical and Clinical Pilot Study

Bryan Oronskya, Dandan Lib, Morgan Wangb, Jenny M. Vo-Phamhic,d, Scott Caroena, Nacer Abrouka, Tony Reida, Babak Alizadeha, Dimitre Hristove, George Fisherf, Ahmed El Kaffasg( )
EpicentRX, La Jolla, CA
Department of Radiology, Stanford University, Stanford, CA, USA
Vagelos College of Physicians & Surgeons, Columbia University, New York, NY, USA
Alta Bates Summit Medical Center, Oakland, CA, USA
Department of Radiation Oncology, Stanford University, Stanford, CA, USA
Department of Medicine, Stanford University, Stanford, CA, USA
Department of Radiology, University of California, San Diego, La Jolla, CA, USA
Show Author Information

Abstract

Background and Purpose

Tumor blood vessels are abnormal and contribute to therapy resistance. RRx-001, an NLRP3 inhibitor, has been shown to remodel tumor vascular properties, enhancing the effects of cytotoxic or immune-promoting agents. However, optimizing timing and dosing of combined treatment regimens is challenging on a patient-by-patient basis; tools for longitudinal imaging to guide such treatment strategy are necessary. Our aim was to evaluate the feasibility of 3D dynamic contrast-enhanced ultrasound (3D DCE-US) to detect acute and subtle tumor perfusion changes following RRx-001 therapy in both mice and humans.

Methods

RRx-001 was administered intraperitoneally at varying doses to determine its effect on perfusion in a mouse model of colon cancer. Blood flow and volume were assessed semi-quantitatively using 3D DCE-US within hours and at subsequent time-points. Additionally, we assessed 3D DCE-US in three patients enrolled in a Phase 2 RRx-001 clinical trial (NCT02096354) by imaging them longitudinally.

Results

In mice (n = 38), 6 mg/kg RRx-001 led to a 1.5% increase in AUC (P = 0.02) and MTT at 24 hours; 12 mg/kg showed no acute effect. In patients (n = 3), 66 mg weekly dosing produced variable perfusion changes within hours to days. Two patients with stable disease showed transient perfusion increases (survival 9-15 months); one with progressive disease showed early perfusion loss (survival 4 months). No grade 3/4 toxicities occurred.

Conclusion

These findings highlight the potential of 3D DCE-US as a noninvasive, bedside tool for real-time monitoring of RRx-001-induced perfusion changes, supporting the feasibility of personalized dosing strategies in both preclinical and clinical settings.

References

【1】
【1】
 
 
Advanced Ultrasound in Diagnosis and Therapy
Pages 169-177

{{item.num}}

Comments on this article

Go to comment

< Back to all reports

Review Status: {{reviewData.commendedNum}} Commended , {{reviewData.revisionRequiredNum}} Revision Required , {{reviewData.notCommendedNum}} Not Commended Under Peer Review

Review Comment

Close
Close
Cite this article:
Oronsky B, Li D, Wang M, et al. 3D Dynamic Contrast-Enhanced Ultrasound for Personalized RRx-001 Dosing: A Preclinical and Clinical Pilot Study. Advanced Ultrasound in Diagnosis and Therapy, 2026, 10(3): 169-177. https://doi.org/10.26599/AUDT.2026.250086

24

Views

4

Downloads

0

Crossref

0

Scopus

Received: 09 August 2025
Revised: 20 August 2025
Accepted: 08 December 2025
Published: 12 October 2026
2576-2508/© AUDT 2026

This is an open-access article distributed under the terms of the Creative Commons Attribution 4.0 International license, which permits unrestricted use, distribution and reproduction in any medium provided that the original work is properly attributed