AI Chat Paper
Note: Please note that the following content is generated by AMiner AI. SciOpen does not take any responsibility related to this content.
{{lang === 'zh_CN' ? '文章概述' : 'Summary'}}
{{lang === 'en_US' ? '中' : 'Eng'}}
Chat more with AI
PDF (1.7 MB)
Collect
Submit Manuscript AI Chat Paper
Show Outline
Outline
Show full outline
Hide outline
Outline
Show full outline
Hide outline
Original Research | Open Access

Inter and Intra-Rater Reliability of Musculoskeletal Ultrasound to Measure Plantar Fascia Thickness in Patients with Established Plantar Fasciitis

Syed Muhammad Yousaf Farooq( ), Kinza Rasool, Syed Amir Gilani, Mehreen Fatima, Sajid Shaheen Malik
Radiography and Imaging Technology, Green International University, Lahore, Pakistan
Office of Research, Innovation and Commercialization, Green International University, Lahore, Pakistan
University Institute of Radiological Sciences & Medical Imaging Technology, Faculty of Allied Health Sciences, The University of Lahore
Department of Medical Diagnostic Imaging, College of Health Sciences, University of Sharjah, Sharjah, UAE
Show Author Information

Abstract

Objective

Plantar fascia (PF) is a thick connective tissue on the plantar surface of the foot that plays a crucial role in maintaining the longitudinal arch. Plantar fasciitis, characterized by inflammation of the medial tuberosity of the calcaneus, is one of the most common causes of heel pain. Imaging is essential for accurate diagnosis, with ultrasonography widely applied to evaluate PF thickness, monitor therapeutic outcomes, and guide interventions. However, its application is limited by operator dependency. This study aimed to investigate the inter- and intra-rater reliability of musculoskeletal ultrasound in measuring PF thickness in patients with plantar fasciitis.

Methods

In this cross-sectional analytical study, 40 participants were enrolled, including 26 females and 14 males. The reliability of PF measurements on different sides was assessed using Cronbach’s alpha and intraclass correlation coefficients (ICC).

Results

A total of 40 participants (age range: 20-60 years) were included in the study. PF thickness in patients with plantar fasciitis measured by Observer 1 ranged from 3.8-6.9 mm (left) and 3.2-6.0 mm (right), whereas measurements by Observer 2 ranged from 2.9-7.1 mm (left) and 3.2-6.0 mm (right). Intra-rater reliability showed ICCs ranging from 0.618-0.857 for Observer 1 and 0.76-0.92 for Observer 2, indicating moderate (> 0.60) to excellent reliability.

Conclusion

PF is a deep structure, and its visualization may be influenced by operator technique. Ultrasound measurement of tendon thickness shows good reliability in patients with established plantar fasciitis.

References

【1】
【1】
 
 
Advanced Ultrasound in Diagnosis and Therapy
Pages 283-289

{{item.num}}

Comments on this article

Go to comment

< Back to all reports

Review Status: {{reviewData.commendedNum}} Commended , {{reviewData.revisionRequiredNum}} Revision Required , {{reviewData.notCommendedNum}} Not Commended Under Peer Review

Review Comment

Close
Close
Cite this article:
Farooq SMY, Rasool K, Gilani SA, et al. Inter and Intra-Rater Reliability of Musculoskeletal Ultrasound to Measure Plantar Fascia Thickness in Patients with Established Plantar Fasciitis. Advanced Ultrasound in Diagnosis and Therapy, 2025, 9(3): 283-289. https://doi.org/10.26599/AUDT.2025.240033

1329

Views

64

Downloads

0

Crossref

0

Scopus

Received: 13 July 2024
Revised: 05 December 2024
Accepted: 27 December 2024
Published: 01 September 2025
2576-2508/© AUDT 2025

This is an open-access article distributed under the terms of the Creative Commons Attribution 4.0 International license, which permits unrestricted use, distribution and reproduction in any medium provided that the original work is properly attributed