AI Chat Paper
Note: Please note that the following content is generated by AMiner AI. SciOpen does not take any responsibility related to this content.
{{lang === 'zh_CN' ? '文章概述' : 'Summary'}}
{{lang === 'en_US' ? '中' : 'Eng'}}
Chat more with AI
PDF (2.6 MB)
Collect
Submit Manuscript AI Chat Paper
Show Outline
Outline
Show full outline
Hide outline
Outline
Show full outline
Hide outline
Open Access

Effects of the air ducts layout in the back wall on the heat transfer and storage characteristics of active heat storage back wall of solar greenhouse

College of Architecture and Urban Planning, Tongji University, Shanghai 200092, China
Institute of Agricultural Facilities and Equipment, Jiangsu Academy of Agricultural Science, Key Laboratory of Protected Agriculture Engineering in the Middle and Lower Reaches of Yangtze River, Ministry of Agriculture and Rural Affairs, Nanjing 210014, China
Fudan Univeristy, Shanghai 200433, China
College of Civil Engineering, Tongji University, Shanghai 200092, China
Key Laboratory of Protected Horticultural Engineering in Northwest, Ministry of Agriculture and Rural Affairs, Department of Horticulture, Northwest A & F University, Yangling 712100, Shaanxi, China

†These authors contribute equally to this research.

Show Author Information

Abstract

Solar greenhouses have been widely developed in China. Active heat storage walls using air ducts arranged in the walls can improve the walls' thermal performance and indoor temperatures of solar greenhouses. In the present work, three kinds of air duct layouts, namely straight-up-and-down duct (Z), fork-shaped top-in- bottom-out distribution duct (DF), and “±”-shaped top-in-side-out distribution duct (CF) are designed. The effect of the three air duct layouts on the heat transfer and storage characteristics of the back wall is studied using the computational fluid dynamics (CFD) method. Results show that after the same time period, the transferred heat amount in the back wall with duct DF is the largest, while that with duct CF is slightly greater than that with duct Z. The temperature of the back walls with air ducts is higher than that without air ducts. The air duct DF is the optimal among the three kinds of air duct layouts. The greenhouse with the duct DF in the back wall shows the most obviously increased indoor average temperature, the highest temperature at night, and the most uniform temperature.

References

【1】
【1】
 
 
International Journal of Agricultural and Biological Engineering
Pages 63-70

{{item.num}}

Comments on this article

Go to comment

< Back to all reports

Review Status: {{reviewData.commendedNum}} Commended , {{reviewData.revisionRequiredNum}} Revision Required , {{reviewData.notCommendedNum}} Not Commended Under Peer Review

Review Comment

Close
Close
Cite this article:
Sun Y, Wu C, Zhu C, et al. Effects of the air ducts layout in the back wall on the heat transfer and storage characteristics of active heat storage back wall of solar greenhouse. International Journal of Agricultural and Biological Engineering, 2025, 18(4): 63-70. https://doi.org/10.25165/j.ijabe.20251804.7785

277

Views

7

Downloads

0

Crossref

0

Web of Science

0

Scopus

Received: 11 July 2023
Accepted: 18 October 2024
Published: 31 August 2025
© The Author(s) 2025

We adopt the latest version of license CC BY 4.0, https://creativecommons.org/licenses/by/4.0/