AI Chat Paper
Note: Please note that the following content is generated by AMiner AI. SciOpen does not take any responsibility related to this content.
{{lang === 'zh_CN' ? '文章概述' : 'Summary'}}
{{lang === 'en_US' ? '中' : 'Eng'}}
Chat more with AI
PDF (623.7 KB)
Collect
Submit Manuscript AI Chat Paper
Show Outline
Outline
Show full outline
Hide outline
Outline
Show full outline
Hide outline
Open Access

Influences of dissolved oxygen sensor position on aeration efficiency of Venturi air injectors in aquaculture and wastewater treatment

Faculty of Environmental Management, Prince of Songkla University, Songkhla 90112, Thailand
Faculty of Science and Industrial Technology, Prince of Songkla University, Surat Thani Campus, Surat Thani, 84000, Thailand
Faculty of Natural Resources, Prince of Songkla University, Songkhla 90112, Thailand
Department of Mechanical Engineering, Delhi Technological University, Delhi, 110042, India
Show Author Information

Abstract

This article concentrates on the aeration efficiency of venturi air injectors in aquaculture or wastewater treatment. This study was designed to investigate the location of the dissolved oxygen (DO) sensor installation, with a focus on investigating the aeration mechanism by studying ten variables, including temperature, pH, oxidation-reduction potential (ORP), electrical conductivity, resistivity, total dissolved solids, salinity, pressure, dissolved oxygen, and the effect of changing the position of DO sensor installations in different locations via oxygen transfer. The water temperature was raised due to the heating of the water pump. It ranged from 29.7°C to 32.78°C, with different temperatures resulting in different oxygen solubility. The pH level increased with the rise in oxygen levels due to an increase in OH concentration, whereas the ORP decreased when oxygen levels rose, increasing the reduction reaction. A study on the effect of changing the position of DO sensor installations in different locations was discovered using oxygen transfer coefficients (KLa) variables. The KLa values at nozzle depths of 15 cm, 30 cm, and 45 cm were 0.0004±0.0001, 0.00042±0.0001, and 0.00136±0.00013, respectively. Therefore, there is a slight difference of KLa value when changing the position of sensor installations. An inappropriate distance between the DO sensor and nozzle installation is able to cause turbulent flow. This event resulted in an incorrect DO value. Moreover, the installation of the DO sensor too far from the nozzle resulted in a low value of DO.

References

【1】
【1】
 
 
International Journal of Agricultural and Biological Engineering
Pages 58-62

{{item.num}}

Comments on this article

Go to comment

< Back to all reports

Review Status: {{reviewData.commendedNum}} Commended , {{reviewData.revisionRequiredNum}} Revision Required , {{reviewData.notCommendedNum}} Not Commended Under Peer Review

Review Comment

Close
Close
Cite this article:
Demeekul N, Puangsuwan K, Rodcharoen E, et al. Influences of dissolved oxygen sensor position on aeration efficiency of Venturi air injectors in aquaculture and wastewater treatment. International Journal of Agricultural and Biological Engineering, 2025, 18(3): 58-62. https://doi.org/10.25165/j.ijabe.20251803.8962

570

Views

18

Downloads

0

Crossref

1

Web of Science

2

Scopus

Received: 27 March 2024
Accepted: 16 March 2025
Published: 30 June 2025
© The Author(s) 2025

We adopt the latest version of license CC BY 4.0, https://creativecommons.org/licenses/by/4.0/