AI Chat Paper
Note: Please note that the following content is generated by AMiner AI. SciOpen does not take any responsibility related to this content.
{{lang === 'zh_CN' ? '文章概述' : 'Summary'}}
{{lang === 'en_US' ? '中' : 'Eng'}}
Chat more with AI
PDF (3.9 MB)
Collect
Submit Manuscript AI Chat Paper
Show Outline
Outline
Show full outline
Hide outline
Outline
Show full outline
Hide outline
Open Access

Posture standardization of pig point cloud based on skeleton extraction and transformation

State Key Laboratory of Swine and Poultry Breeding Industry, Guangzhou, Guangdong 510640, China
College of Mathematics Informatics, South China Agricultural University, Guangzhou 510642, China
National Engineering Research Center for Swine Breeding Industry, Guangzhou 510642, China
Guangdong Zhongxin Breeding Technology Co.,Ltd, Guangzhou 511458, China
School of Foreign Studies, South China Agricultural University, Guangzhou 510642, China
Show Author Information

Abstract

Pig body measurement is an important evaluation criterion for breeding and production management. Automatic measurement algorithms for pig body sizes exhibit sensitivity to the point cloud posture, but non-standard pig postures may result in inaccurate joint point localization in body measurement, further affecting measurement accuracy and the commercial application of these algorithms. To address this challenge, this paper proposed a pig point cloud posture transformation method based on pig’s skeleton model to adjust non-standard postures before conducting body size measurements. The method utilized an improved L1-median skeleton model to extract the three-dimensional skeleton of the pig point cloud, capturing the skeleton joint points on the target pig’s head, body, and limbs. By binding the skeleton joint points with the local point cloud and using rotation matrices, non-standard postures were adjusted to standard ones, enabling accurate body size measurements. The experimental results demonstrated that the average relative errors between the transferred posture and the original standard posture were reduced to 0.89% in body length, 0.76% in body width (front), 1% in body width (back), 0.89% in body height (front), 1.7% in body height (back), 2.03% in thoracic circumference, 3.37% in abdominal circumference, and 1.89% in rump circumference. To conclude, the posture standardization transfer method can significantly reduce errors in important body size parameters such as body length, body height, and body width. The method displays a greater stability and robustness compared to existing posture normalization and regression adjustment methods, providing both guidance and insight for future research in intelligent agriculture.

References

【1】
【1】
 
 
International Journal of Agricultural and Biological Engineering
Pages 63-74

{{item.num}}

Comments on this article

Go to comment

< Back to all reports

Review Status: {{reviewData.commendedNum}} Commended , {{reviewData.revisionRequiredNum}} Revision Required , {{reviewData.notCommendedNum}} Not Commended Under Peer Review

Review Comment

Close
Close
Cite this article:
Zhu J, Chen Z, Yin L, et al. Posture standardization of pig point cloud based on skeleton extraction and transformation. International Journal of Agricultural and Biological Engineering, 2025, 18(2): 63-74. https://doi.org/10.25165/j.ijabe.20251802.8644

343

Views

22

Downloads

1

Crossref

1

Web of Science

0

Scopus

Received: 12 November 2023
Accepted: 03 December 2024
Published: 30 April 2025
© The Author(s) 2025

We adopt the latest version of license CC BY 4.0, https://creativecommons.org/licenses/by/4.0/