Article | Open Access

A fast configuration method for external cooling system of power transformer considering energy loss

Lujia Wang1( )Mengzhi Sun1Zhenlu Cai2Haitao Yang3Xibo Wu4
School of Electrical Engineering, China University of Mining and Technology, Xuzhou 221116, China
State Grid Jiangsu Electric Power Company Ltd. Lianshui County Power Supply Branch, Huai’an 223400, China
Electric Power Research Institute, State Grid Anhui Electric Power Company Ltd., State Grid Corporation of China, Hefei 230061, China
Electric Power Research Institute of State Grid Henan Electric Power Company, Zhengzhou 450000, China
Show Author Information

Abstract

Radiator cooling configurations need to account for both efficient heat dissipation and energy conservation requirements. Rapid and rational determination of cooling system configurations constitutes a critical aspect of transformer design, enhancing electrical power energy utilization efficiency. Computational fluid dynamics (CFD) is widely recognized as a well-established technique for simulating and optimizing heat dissipation systems. However, this approach is time-consuming because of pre-processing procedures, such as meshing. This paper proposes a fast iterative optimization model for calculating the outlet oil temperature and airflow distribution. Based on the analytical model results, this paper identifies the optimal energy-saving range for radiator cooling configurations, incorporating the cooperative effects of cooling efficiency, air pressure drop during heat transfer, and inlet–outlet temperature difference. The analytical model demonstrated errors in energy dissipation and temperature difference calculations within an acceptable range. The calculation time was reduced by more than 99%. Radiator configurations within the optimal range effectively minimize energy waste while meeting the target temperature difference and enhancing cooling efficiency. Finally, the PC2600-22/520 radiator was utilized to validate the accuracy of the analytical model and the rationality of the co-optimal intervals.

References

【1】
【1】
 
 
iEnergy
Pages 269-277

{{item.num}}

Comments on this article

Go to comment

< Back to all reports

Review Status: {{reviewData.commendedNum}} Commended , {{reviewData.revisionRequiredNum}} Revision Required , {{reviewData.notCommendedNum}} Not Commended Under Peer Review

Review Comment

Close
Close
Cite this article:
Wang L, Sun M, Cai Z, et al. A fast configuration method for external cooling system of power transformer considering energy loss. iEnergy, 2025, 4(4): 269-277. https://doi.org/10.23919/IEN.2025.0028

1618

Views

99

Downloads

0

Crossref

0

Web of Science

0

Scopus

Received: 22 July 2025
Revised: 06 September 2025
Accepted: 23 September 2025
Published: 06 November 2025
© The author(s) 2025.

This is an open access article under the CC BY license (http://creativecommons.org/licenses/by/4.0/).