AI Chat Paper
Note: Please note that the following content is generated by AMiner AI. SciOpen does not take any responsibility related to this content.
{{lang === 'zh_CN' ? '文章概述' : 'Summary'}}
{{lang === 'en_US' ? '中' : 'Eng'}}
Chat more with AI
PDF (72.2 MB)
Collect
Submit Manuscript AI Chat Paper
Show Outline
Outline
Show full outline
Hide outline
Outline
Show full outline
Hide outline
Regular Paper

Optimal Control Strategy for Frequency Response of V2G Grid-connected Inverter Considering SOC Characteristics

Peijin Liu1Zhengming Feng1( )Ping Wei2Hongxian Li1Qianjun Liu1Yong Chen3
School of Mechanical and Electrical Engineering, Xi’an University of Architecture and Technology, Xi’an 710055, China
Northwest Branch of State Grid Corporation of China, Xi’an 710048, China
DC Power Distribution and Consumption Technology Research Center of Guangdong Power Grid Co., Ltd., Guangzhou 519000, China
Show Author Information

Abstract

New energy-vehicle charging and discharging units in vehicle to grid (V2G) application scenarios experience long and large transient fluctuations in power and frequency at their power injection points. Furthermore, the power matching degree is low, which has a serious impact on the V2G support performance. This paper proposes a two-step model prediction-virtual synchronous machine (MPC-VSG) control strategy that considers the SOC of the charging and discharging unit. First, the VSG equivalent model of the V2G grid-connected inverter is established, and the power weight coefficients of the charging and discharging unit SOC participating in frequency regulation are obtained by analyzing its characteristics. Second, the power change prediction value is obtained from the VSG model, and the two-step prediction of the reference frequency is performed to reduce the error of the reference value remaining unchanged at the instant of sudden power change. Minimizing the sum of squares of real-time output power deviations and frequency fluctuations as a cost function to compensate for the optimal active losses and suppress the frequency transient fluctuations. Finally, simulation analysis is carried out under the working conditions of island mode operation, V2G grid-connected operation, and wind power multi-energy complementary operation, and an experimental verification of the inverter part is carried out to verify the effectiveness and superiority of the proposed control strategy.

References

【1】
【1】
 
 
Chinese Journal of Electrical Engineering
Pages 127-145

{{item.num}}

Comments on this article

Go to comment

< Back to all reports

Review Status: {{reviewData.commendedNum}} Commended , {{reviewData.revisionRequiredNum}} Revision Required , {{reviewData.notCommendedNum}} Not Commended Under Peer Review

Review Comment

Close
Close
Cite this article:
Liu P, Feng Z, Wei P, et al. Optimal Control Strategy for Frequency Response of V2G Grid-connected Inverter Considering SOC Characteristics. Chinese Journal of Electrical Engineering, 2025, 11(3): 127-145. https://doi.org/10.23919/CJEE.2025.000169

797

Views

57

Downloads

1

Crossref

1

Scopus

0

CSCD

Received: 10 January 2024
Revised: 29 April 2024
Accepted: 16 May 2024
Published: 30 September 2025
© 2025 China Machinery Industry Information Institute