AI Chat Paper
Note: Please note that the following content is generated by AMiner AI. SciOpen does not take any responsibility related to this content.
{{lang === 'zh_CN' ? '文章概述' : 'Summary'}}
{{lang === 'en_US' ? '中' : 'Eng'}}
Chat more with AI
PDF (1.1 MB)
Collect
Submit Manuscript AI Chat Paper
Show Outline
Outline
Show full outline
Hide outline
Outline
Show full outline
Hide outline
Open Access

Wavelet Synchro-squeezing Transform and Dynamic Threshold Supported Symmetrical Power Swing Technique for Modern Transmission Network

Monalisa Biswal1( )Kumar Raja Andanapalli1Papia Ray2
Department of Electrical Engineering, National Institute of Technology Raipur, Chhattisgarh 492010, India
Department of Electrical Engineering, Veer Surendra Sai University of Technology, Burla Sambalpur 768018, India
Show Author Information

Abstract

Distance relays are prone to symmetrical power swing phenomenon. To mitigate this issue, a dynamic threshold-supported algorithm is proposed. A single logic is not supposed to be secure for all cases. Thus, a supervisory algorithm, as proposed in this study, can aid in the improvement of the immunity of the relay during swing cases and be sensitive to symmetrical faults. In the developed stages, a three-phase power signal was used and processed in two different steps: (ⅰ) extraction of the effective intrinsic mode function (IMF) selected from the Kurtosis analysis using the wavelet synchro-squeezing transform, and (ⅱ) estimation of the average Euclidean distance index using the absolute values of the decomposed IMF’s. The adaptive threshold facilitated resistance to swing situations. At the onset of a symmetrical fault, the proposed algorithm efficiently discriminated among events using a dynamic threshold. The IEEE 39-bus test system and Indian Eastern Power Grid networks were modelled using PSCAD software, and cases were generated to test the efficacy of the method. The impact of the proposed method on a large-scale wind farm was also evaluated. A comparative analysis with other existing methods revealed the security and dependability of the proposed method.

Graphical Abstract

References

【1】
【1】
 
 
Chinese Journal of Electrical Engineering
Pages 30-43

{{item.num}}

Comments on this article

Go to comment

< Back to all reports

Review Status: {{reviewData.commendedNum}} Commended , {{reviewData.revisionRequiredNum}} Revision Required , {{reviewData.notCommendedNum}} Not Commended Under Peer Review

Review Comment

Close
Close
Cite this article:
Biswal M, Andanapalli KR, Ray P. Wavelet Synchro-squeezing Transform and Dynamic Threshold Supported Symmetrical Power Swing Technique for Modern Transmission Network. Chinese Journal of Electrical Engineering, 2024, 10(2): 30-43. https://doi.org/10.23919/CJEE.2024.000064

763

Views

71

Downloads

3

Crossref

5

Scopus

0

CSCD

Received: 30 May 2023
Revised: 03 December 2023
Accepted: 19 December 2023
Published: 30 June 2024
© 2024 China Machinery Industry Information Institute