Accurate 3D Thermal Network Development for Direct-drive Outer-rotor Hybrid-PM Flux-switching Generator

Ali Zarghani1Mohammad Farahzadi2Aghil Ghaheri1( )Karim Abbaszadeh3
Faculty of Electrical Engineering, Shahid Beheshti University, Tehran 1983969411, Iran
Faculty of Electrical Engineering, University of Science and Culture, Tehran 1461968151, Iran
Department of Electrical Engineering, K. N. Toosi University of Technology, Tehran 1631714191, Iran
Show Author Information

Abstract

Heat and thermal problems are major obstacles to achieving high power density in compact permanent magnet (PM) topologies. Consequently, a comprehensive, accurate, and rapid temperature rise estimation method is required for novel electric machines to ensure safe and reliable operations. A unique three-dimensional (3D) lumped parameter thermal network (LPTN) is presented for accurate thermal modeling of a newly developed outer-rotor hybrid-PM flux switching generator (OR-HPMFSG) for direct-drive applications. First, the losses of the OR-HPMFSG are calculated using 3D finite element analysis (FEA). Subsequently, all machine components considering the thermal contact resistance, anisotropic thermal conductivity of materials, and various heat flow paths are comprehensively modeled based on the thermal resistances. In the proposed 3-D LPTN, internal nodes are considered to predict the average temperature as well as the hot spots of all active and passive components. Experimental measurements are performed on a prototype OR-HPMFSG to validate the efficiency of the 3-D LPTN. A comparison of the results at various operating points between the developed 3-D LPTN, experimental test, and FEA indicates that the 3-D LPTN quickly approximates the hotspot and mean temperature of all components under both transient and steady states with high accuracy.

Graphical Abstract

References

【1】
【1】
 
 
Chinese Journal of Electrical Engineering
Pages 80-92

{{item.num}}

Comments on this article

Go to comment

< Back to all reports

Review Status: {{reviewData.commendedNum}} Commended , {{reviewData.revisionRequiredNum}} Revision Required , {{reviewData.notCommendedNum}} Not Commended Under Peer Review

Review Comment

Close
Close
Cite this article:
Zarghani A, Farahzadi M, Ghaheri A, et al. Accurate 3D Thermal Network Development for Direct-drive Outer-rotor Hybrid-PM Flux-switching Generator. Chinese Journal of Electrical Engineering, 2024, 10(2): 80-92. https://doi.org/10.23919/CJEE.2024.000059

981

Views

87

Downloads

14

Crossref

15

Scopus

1

CSCD

Received: 09 October 2023
Revised: 30 November 2023
Accepted: 15 January 2024
Published: 30 June 2024
© 2024 China Machinery Industry Information Institute