AI Chat Paper
Note: Please note that the following content is generated by AMiner AI. SciOpen does not take any responsibility related to this content.
{{lang === 'zh_CN' ? '文章概述' : 'Summary'}}
{{lang === 'en_US' ? '中' : 'Eng'}}
Chat more with AI
PDF (4.6 MB)
Collect
Submit Manuscript AI Chat Paper
Show Outline
Outline
Show full outline
Hide outline
Outline
Show full outline
Hide outline
Original Article | Open Access

Safety and efficacy of intraoperative radiation therapy using a low-energy X-ray source for resectable pancreatic cancer: an interim evaluation of an ongoing prospective phase Ⅱ study

Xingyun Chen1,*Shuo Li1,*Chuntao Gao1Wei Wang2Haorui Li1Yuxiao Liu1Rui Liu3 ( )Jihui Hao1 ( )
Department of Pancreatic Cancer, Tianjin Medical University Cancer Institute & Hospital, National Clinical Research Center for Cancer, Key Laboratory of Cancer Prevention and Therapy, Tianjin, Tianjin’s Clinical Research Center for Cancer, Tianjin 300060, China
Department of Radiation Oncology, Tianjin Medical University Cancer Institute & Hospital, National Clinical Research Center for Cancer, Key Laboratory of Cancer Prevention and Therapy, Tianjin, Tianjin’s Clinical Research Center for Cancer, Tianjin 300060, China
Department of Gastrointestinal Oncology, Tianjin Medical University Cancer Institute & Hospital, National Clinical Research Center for Cancer, Key Laboratory of Cancer Prevention and Therapy, Tianjin, Tianjin’s Clinical Research Center for Cancer, Tianjin Key Laboratory of Digestive Cancer, Tianjin 300060, China

*These authors contributed equally to this work.

Show Author Information

Abstract

Objective

The role of intraoperative radiation therapy (IORT) in the management of resectable pancreatic cancer (RPC) remains unclear. To date, the application of IORT using a low-energy X-ray source has not been extensively investigated. Therefore, this study was conducted to evaluate the safety and efficacy of IORT using a 50 kV X-ray source in treating RPC.

Methods

Patients with RPC who underwent radical pancreatectomy and IORT were enrolled. The primary endpoint was time to treatment failure (TTF) survival, whereas the secondary endpoints were safety and overall survival (OS).

Results

By November 2023, 35 patients with RPC were treated according to the study protocol. The median TTF was 11.67 months, whereas the median OS for the cohort was 22.2 months. The local recurrence rate was 20%. The most common postoperative complication was pancreatic fistula. The incidence of delayed gastric emptying was 20%. Within 30 days after surgery, one patient experienced abdominal pain, another experienced vomiting, and one died because of abdominal infection and a grade C pancreatic fistula. Carcinoembryonic antigen (CEA) and D-dimer levels significantly correlated with TTF and OS in multivariate analyses. The carbohydrate antigen 19-9 (CA19-9) level was another prognostic factor significantly associated with OS. Patients with low D-dimer and normal CA19-9 levels showed prolonged OS with an IORT dose ≤ 15 Gy.

Conclusions

This study supports use of IORT with a 50 kV X-ray source in treating RPC. IORT using a low-energy X-ray source was well-tolerated and feasible. Additionally, D-dimer, CEA, and CA19-9 levels may help identify patient profiles potentially benefitting from IORT.

References

【1】
【1】
 
 
Cancer Biology & Medicine
Pages 67-76

{{item.num}}

Comments on this article

Go to comment

< Back to all reports

Review Status: {{reviewData.commendedNum}} Commended , {{reviewData.revisionRequiredNum}} Revision Required , {{reviewData.notCommendedNum}} Not Commended Under Peer Review

Review Comment

Close
Close
Cite this article:
Chen X, Li S, Gao C, et al. Safety and efficacy of intraoperative radiation therapy using a low-energy X-ray source for resectable pancreatic cancer: an interim evaluation of an ongoing prospective phase Ⅱ study. Cancer Biology & Medicine, 2025, 22(1): 67-76. https://doi.org/10.20892/j.issn.2095-3941.2024.0287

468

Views

33

Downloads

0

Crossref

1

Web of Science

0

Scopus

Received: 25 July 2024
Accepted: 25 November 2024
Published: 03 January 2025
© 2025 The Authors.

Creative Commons Attribution-NonCommercial 4.0 International License