Shaking Table Test of Subway Station Structure Passing through Above-Ground Building

Xuechuan Han1,2( ), Lianjin Tao3, Yu Zhang3, Yongping Xie1,2
College of Urban Geology and Engineering, Hebei GEO University, Shijiazhuang 050031, P. R. China
Hebei Technology Innovation Center for Intelligent Development and Control of Underground Built Environment, Shijiazhuang 050031, P. R. China
Key Laboratory of Urban Security and Disaster Engineering of Ministry of Education, Beijing University of Technology, Beijing 100124, P. R. China
Show Author Information

Abstract

In order to study the seismic dynamic response law of subway station under above-ground building, shaking table test with similarity ratio of 1:40 was carried out in silty sand, and the acceleration, strain and dynamic earth pressure during the test are analyzed in detail. It is shown that: (1) With the increase of earthquake intensity, the peak acceleration at the same monitoring point is gradually increasing, but the amplification coefficient and variation amplitude of acceleration are gradually decreasing; (2) The maximum acceleration amplification coefficient of soil is located on the ground surface. With the increase of earthquake intensity, the position of the minimum acceleration amplification coefficient gradually transits from the bottom of the model to the location of the structure; (3) The strain of the model structure gradually increased with the increase of seismic intensity, and the relatively large strains mainly appeared at the intersection of side walls, middle columns and plates, especially at the end of middle columns; (4) The peak value of dynamic earth pressure in the middle of side wall is greater than the top and bottom, and the lateral stiffness or anti deformation capacity at the middle plate of the station should be appropriately enhanced. The research results can provide a reference for the seismic design and analysis of similar subway station structure.

CLC number: TU93 Document code: A Article ID: 1673-0836(2024)01-0143-09

References

【1】
【1】
 
 
Chinese Journal of Underground Space and Engineering
Pages 143-151

{{item.num}}

Comments on this article

Go to comment

< Back to all reports

Review Status: {{reviewData.commendedNum}} Commended , {{reviewData.revisionRequiredNum}} Revision Required , {{reviewData.notCommendedNum}} Not Commended Under Peer Review

Review Comment

Close
Close
Cite this article:
Han X, Tao L, Zhang Y, et al. Shaking Table Test of Subway Station Structure Passing through Above-Ground Building. Chinese Journal of Underground Space and Engineering, 2024, 20(1): 143-151. https://doi.org/10.20174/j.juse.2024.01.016

569

Views

1

Downloads

0

Crossref

0

Scopus

0

CSCD

Received: 27 September 2023
Published: 01 February 2024
© 2024 Chinese Journal of Underground Space and Engineering

This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).