AI Chat Paper
Note: Please note that the following content is generated by AMiner AI. SciOpen does not take any responsibility related to this content.
{{lang === 'zh_CN' ? '文章概述' : 'Summary'}}
{{lang === 'en_US' ? '中' : 'Eng'}}
Chat more with AI
PDF (8.7 MB)
Collect
Submit Manuscript AI Chat Paper
Show Outline
Outline
Show full outline
Hide outline
Outline
Show full outline
Hide outline
Open Access

Study on the Risk of Cross-Infection and Reduction Strategies for the Queueing Population in Subway Stations

Chen Lin1, Juan Yang2, Baoyu Li2, Biao Zhang3, Zhengtao Ai1( )
College of Civil Engineering, Hunan University, Changsha 410082, P. R. China
Changsha Metro Group Co., Ltd., Changsha 410000, P. R. China
China Railway Shanghai Design Institute Group Co., Ltd., Shanghai 200070, P. R. China
Show Author Information

Abstract

Subway stations are characterized by poor ventilation, high density of people, and close exposure, making them one of the high-risk places for the spread of infectious diseases. Based on the CFD (Computational Fluid Dynamic) method, this paper studied the effects of mask-wearing, personnel distance, ventilation volume, and air supply distance on the risk of cross-infection for people in queues in different risk areas of subway stations. The risk of cross-infection in the high-density queue in the subway station was evaluated and the reduction strategy was proposed. The results showed that in the process of close contact in the ticketing area without masks, the infected persons not only exposed the people in front of them to high risk but also increased the exposure risk of people on both sides of them. There is still a high risk of infection during close security checks, and it is recommended that security personnel wear masks. The prevention and control effect of comprehensive ventilation in subway stations is affected by air supply distance and ventilation volume. For areas close to the air supply outlet (< 0.5 m), increasing ventilation volume can significantly reduce the risk of infection. For the area far from the air outlet (>1 m), the effect of increasing the ventilation volume to reduce the risk is poor. The findings of this study are expected to provide a basis for the formulation of reasonable prevention and control measures, help relieve the pressure of epidemic prevention and control in subway stations, and save prevention and control costs.

CLC number: U231.5 Document code: A Article ID: 1673-0836(2023)05-1738-13

References

【1】
【1】
 
 
Chinese Journal of Underground Space and Engineering
Pages 1738-1750

{{item.num}}

Comments on this article

Go to comment

< Back to all reports

Review Status: {{reviewData.commendedNum}} Commended , {{reviewData.revisionRequiredNum}} Revision Required , {{reviewData.notCommendedNum}} Not Commended Under Peer Review

Review Comment

Close
Close
Cite this article:
Lin C, Yang J, Li B, et al. Study on the Risk of Cross-Infection and Reduction Strategies for the Queueing Population in Subway Stations. Chinese Journal of Underground Space and Engineering, 2023, 19(5): 1738-1750. https://doi.org/10.20174/j.juse.2023.05.035

517

Views

1

Downloads

0

Crossref

0

Scopus

0

CSCD

Received: 29 March 2023
Published: 01 October 2023
© 2023 Chinese Journal of Underground Space and Engineering

This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).