AI Chat Paper
Note: Please note that the following content is generated by AMiner AI. SciOpen does not take any responsibility related to this content.
{{lang === 'zh_CN' ? '文章概述' : 'Summary'}}
{{lang === 'en_US' ? '中' : 'Eng'}}
Chat more with AI
PDF (8.2 MB)
Collect
Submit Manuscript AI Chat Paper
Show Outline
Outline
Show full outline
Hide outline
Outline
Show full outline
Hide outline
Open Access

Research on the Mechanical Properties of Multi-Scale Polypropylene Fiber Reinforced Concrete Secondary Lining

Debin Sun1, Peiwen Yang2, Lianxi Ren3,4( ), Ninghui Liang4, Liu Liu4
CCCC Asset Management Co., Ltd., Beijing 100013, P. R. China
CCCC Road and Bridge Construction Co., Ltd., Beijing 101107, P. R. China
Shanghai Tunnel Engineering and Rail Transit Design & Research Institute, Shanghai 200235, P. R. China
School of Civil Engineering, Chongqing University, Chongqing 400045, P. R. China
Show Author Information

Abstract

When lining cracking, water leakage, corrosion and other diseases occur in operating tunnels, the treatment of lining diseases should not only consider the stress condition of the supporting structure, but also the performance of the supporting materials. Based on a tunnel secondary lining replacement project, a field test of the secondary lining of Multi-scale Polypropylene Fiber Reinforced Concrete (MPFRC) was carried out. The long-term observation and data collection were carried out on the lining strength, tunnel appearance, contact pressure between the primary support and the secondary lining, and concrete strain. The mechanical characteristics of the fiber-reinforced concrete secondary lining structure were studied. The results show that the strength of fiber to concrete is obviously improved under the condition of this ratio, and the compressive strength, split tensile strength and flexural strength have increased by 7.51%, 11.45% and 26.95%, respectively. Secondly, the maximum contact pressures of the ordinary concrete section and the fiber-reinforced concrete section are both at the arch foot, which are 282.63 kPa and 231.83 kPa, respectively. Thirdly, the strain amplitude of fiber-reinforced concrete is about 45.45% smaller than that of ordinary concrete, its strain curve is relatively flat, and the value is more stable. MPFRC enables the safety of lining structures to be enhanced. The research can provide a reference for the disease control of similar projects.

CLC number: U454;TU528 Document code: A Article ID: 1673-0836(2023)03-0833-11

References

【1】
【1】
 
 
Chinese Journal of Underground Space and Engineering
Pages 833-843

{{item.num}}

Comments on this article

Go to comment

< Back to all reports

Review Status: {{reviewData.commendedNum}} Commended , {{reviewData.revisionRequiredNum}} Revision Required , {{reviewData.notCommendedNum}} Not Commended Under Peer Review

Review Comment

Close
Close
Cite this article:
Sun D, Yang P, Ren L, et al. Research on the Mechanical Properties of Multi-Scale Polypropylene Fiber Reinforced Concrete Secondary Lining. Chinese Journal of Underground Space and Engineering, 2023, 19(3): 833-843. https://doi.org/10.20174/j.juse.2023.03.014

596

Views

2

Downloads

0

Crossref

0

Scopus

0

CSCD

Received: 06 January 2023
Published: 01 June 2023
© 2023 Chinese Journal of Underground Space and Engineering

This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).