AI Chat Paper
Note: Please note that the following content is generated by AMiner AI. SciOpen does not take any responsibility related to this content.
{{lang === 'zh_CN' ? '文章概述' : 'Summary'}}
{{lang === 'en_US' ? '中' : 'Eng'}}
Chat more with AI
PDF (2.6 MB)
Collect
Submit Manuscript AI Chat Paper
Show Outline
Outline
Show full outline
Hide outline
Outline
Show full outline
Hide outline
Open Access

Study on Anti-floating Failure Mode of Subway Open-Cut Structure in Water-Rich Stratum

Wanjun Zang1,2( ), Xiwen Zhao1,2, Qiyun Wang3, Yulu Zhang1,2, Nanxiong Xiao1,2
School of Civil Engineering, Fujian University of Technology, Fuzhou 350118, P.R. China
Key Laboratory of Underground Engineering, Fujian Province University, Fuzhou 350118, P.R. China
School of Civil and Architectural Engineering, Hunan Institute of Technology, Hengyang, Hunan 421002, P.R. China
Show Author Information

Abstract

The anti-floating design of different stratum structures varies greatly. Anti-floating problems of subway stations in water-rich stratum should arouse people’s attention. The anti-floating failure mode of the subway station in a water-rich stratum is obtained by combining the indoor model test with ABAQUS finite element simulation, and specific anti-floating measures are suggested based on the findings. The typical Xiamen urban rail transit station is used as the research object. The results show that the overall anti-floating failure mechanism of the subway station situated in a water-rich stratum is caused by friction on the sidewall of the station. The floating displacement growth rate is accelerating, yet the structure is not suddenly floating. The strain at the floor and column joint is larger than other parts of the floor. The trend of pore water pressure at the soil under the bottom floor is consistent with the water pressure after the station structure floats. The pore water pressure at the soil under the bottom floor needs to be reduced, and the reduction coefficient is about 0.79-0.85. In the anti-floating design, it should be considered to set up retaining structures such as continuous underground walls to change the seepage path and increase the head loss.

CLC number: TU921 Document code: A Article ID: 1673-0836(2023)01-0302-07

References

【1】
【1】
 
 
Chinese Journal of Underground Space and Engineering
Pages 302-308

{{item.num}}

Comments on this article

Go to comment

< Back to all reports

Review Status: {{reviewData.commendedNum}} Commended , {{reviewData.revisionRequiredNum}} Revision Required , {{reviewData.notCommendedNum}} Not Commended Under Peer Review

Review Comment

Close
Close
Cite this article:
Zang W, Zhao X, Wang Q, et al. Study on Anti-floating Failure Mode of Subway Open-Cut Structure in Water-Rich Stratum. Chinese Journal of Underground Space and Engineering, 2023, 19(1): 302-308. https://doi.org/10.20174/j.juse.2023.01.034

565

Views

8

Downloads

0

Crossref

0

Scopus

0

CSCD

Received: 19 October 2022
Published: 01 February 2023
© 2023 Chinese Journal of Underground Space and Engineering

This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).