AI Chat Paper
Note: Please note that the following content is generated by AMiner AI. SciOpen does not take any responsibility related to this content.
{{lang === 'zh_CN' ? '文章概述' : 'Summary'}}
{{lang === 'en_US' ? '中' : 'Eng'}}
Chat more with AI
PDF (4.8 MB)
Collect
Submit Manuscript AI Chat Paper
Show Outline
Outline
Show full outline
Hide outline
Outline
Show full outline
Hide outline
Open Access

Study on the Damage Effect of Subway Station Roof under Gas Pipeline Explosion

Jianhua Cheng1,2, Yingkang Weng1, Hui Qian1,3( ), Yaqi Ye1,2, Wenwen Bao1
School of Civil Engineering, Henan Polytechnic University, Jiaozuo, Henan 454003, P. R. China
International Joint Research Laboratory of Henan Province for Underground Space Development and Disaster Prevention, Jiaozuo, Henan 454003, P. R. China
School of Civil Engineering, Zhengzhou University, Zhengzhou 450001, P. R. China
Show Author Information

Abstract

This study investigates the impact of varying soil cover thicknesses on the damage sustained by subway station roofs during leakage and explosion events involving sub-high-pressure gas pipelines. Taking a station on Zhengzhou Metro Line 12 as the case study, the TNT equivalent method was employed to quantify the explosion load. A full-scale numerical simulation model was developed using ANSYS / LS-DYNA, and the accuracy of the finite element model was validated through experimental data and theoretical calculations. The influence of different soil cover thicknesses on the structure of the subway station roof slab under the action of medium-pressure gas pipeline leakage and explosion was simulated. The damage effect of the subway station roof slab was comprehensively analyzed from three aspects: structural damage, failure mode, and dynamic response. The damage function of the subway station roof slab was established by the dimensional analysis method, and the relationship between the damage of the subway station roof slab and the ratio of soil cover thickness was analyzed through the damage threshold line. It was found that the ratio of soil cover thickness on the upper part of the subway station roof slab has a significant impact on the damage effect of the subway station roof slab. The research results provide a reference basis for evaluating the explosion resistance capacity of subway stations and designing and implementing efficient protection strategies.

CLC number: TU375.2 Document code: A Article ID: 1673-0836(2026)04-1469-12

References

【1】
【1】
 
 
Chinese Journal of Underground Space and Engineering
Pages 1469-1480

{{item.num}}

Comments on this article

Go to comment

< Back to all reports

Review Status: {{reviewData.commendedNum}} Commended , {{reviewData.revisionRequiredNum}} Revision Required , {{reviewData.notCommendedNum}} Not Commended Under Peer Review

Review Comment

Close
Close
Cite this article:
Cheng J, Weng Y, Qian H, et al. Study on the Damage Effect of Subway Station Roof under Gas Pipeline Explosion. Chinese Journal of Underground Space and Engineering, 2026, 22(4): 1469-1480. https://doi.org/10.20174/j.JUSE.2026.04.35

2

Views

0

Downloads

0

Crossref

0

Scopus

0

CSCD

Received: 21 November 2025
Published: 01 August 2026
© 2026 Chinese Journal of Underground Space and Engineering

This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).