AI Chat Paper
Note: Please note that the following content is generated by AMiner AI. SciOpen does not take any responsibility related to this content.
{{lang === 'zh_CN' ? '文章概述' : 'Summary'}}
{{lang === 'en_US' ? '中' : 'Eng'}}
Chat more with AI
PDF (3.3 MB)
Collect
Submit Manuscript AI Chat Paper
Show Outline
Outline
Show full outline
Hide outline
Outline
Show full outline
Hide outline
Open Access

Deformation Control Standards of CFG Pile Composite Foundation in Loess Region

Liang Zhang1, Tiehang Wang1( ), Zaikun Zhao2, Jiabin Ruan1, Shaochong Wei1
School of Civil Engineering, Xi'an University of Architecture and Technology, Xi'an 710021, P. R. China
College of Civil and Architectural Engineering, Guangxi University of Science and Technology, Liuzhou, Guangxi 545006, P. R. China
Show Author Information

Abstract

The deformation control standard for composite foundation load tests was originally established for multi-story and low high-rise buildings. However, the standard continues to be applied to high-rise and Class A structures(above 30 stories) without accounting for the increase in foundation settlement under higher structural loads, raising concerns about its applicability. High-rise buildings with plain concrete pile composite foundations in loess regions often experience significant settlement, sometimes leading to settlement-related structural issues. It is necessary to discuss the deformation control standards from a design theoretical perspective.Firstly, the shear stress-shear displacement relationship is determined through interface shear tests and a mechanical model for the contact interface is derived. A numerical simulation model incorporating pile-soil interaction is then developed for both group-pile and single-pile composite foundations. The settlement ratio between composite foundations and load tests is calculated. The numerical results are validated by comparing the settlement ratios of the composite foundation in existing cases with those from the load tests. Finally, a revised deformation control standard for single-pile composite foundation load tests in loess regions is proposed, along with recommended values. The results show that: The settlement ratio increases significantly with structural load; Soil properties around the piles have minimal impact on settlement ratio; The settlement ratio is primarily governed by load, and as load increases, the settlement observed in load tests becomes less representative of the actual behavior of group-pile composite foundations; A recommended deformation control standard table for load tests on plain concrete pile composite foundations in loess regions is provided based on structural load considerations.

CLC number: TU444 Document code: A Article ID: 1673-0836(2026)04-1372-08

References

【1】
【1】
 
 
Chinese Journal of Underground Space and Engineering
Pages 1372-1379

{{item.num}}

Comments on this article

Go to comment

< Back to all reports

Review Status: {{reviewData.commendedNum}} Commended , {{reviewData.revisionRequiredNum}} Revision Required , {{reviewData.notCommendedNum}} Not Commended Under Peer Review

Review Comment

Close
Close
Cite this article:
Zhang L, Wang T, Zhao Z, et al. Deformation Control Standards of CFG Pile Composite Foundation in Loess Region. Chinese Journal of Underground Space and Engineering, 2026, 22(4): 1372-1379. https://doi.org/10.20174/j.JUSE.2026.04.25

3

Views

0

Downloads

0

Crossref

0

Scopus

0

CSCD

Received: 15 September 2025
Published: 01 August 2026
© 2026 Chinese Journal of Underground Space and Engineering

This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).