Experimental Research on Fire Performance of Hybrid Fiber Concrete Corbels for Flue Plate

Chengxiang XU1,2( ), Qianhong WANG1, Qiqi XU3, Xuepeng JIANG3
School of Urban Construction, Wuhan University of Science and Technology, Wuhan 430065, P. R. China
Hubei Engineering Research Center for Urban Renewal, Wuhan 430065, P. R. China
School of Resources and Environmental Engineering, Wuhan University of Science and Technology, Wuhan 430081, P. R. China
Show Author Information

Abstract

To improve the fire safety of corbels for flue plates, six corbels were designed and fabricated. For the test group, corbels under constant load were heated according to the standard fire temperature-rise curve for 120 minutes, followed by natural cooling. After that, static loading destructive tests were conducted with corbels not subjected to high temperatures as the control group. Failure processes of the corbels were observed. The hybrid effects of steel fibers and polypropylene fibers were explored. The results show that: The steel-polypropylene hybrid fiber concrete corbels for flue plates are superior to plain concrete corbels in terms of delaying the temperature rise, enhancing the anti-spalling performance, and other aspects. Under the effect of two-hour heating, the corbels did not show obvious displacement or overall collapse. After being heated and loaded, the corbels did not show the characteristics of flexural failure or shear failure, but their internal reinforcement bar plantings exhibited a bond-slip failure mode. Residual bearing capacities of the corbels with double-doped fiber, single-doped fiber, and plain concrete after high temperature were 85.71%,79.08% and 64.90%, respectively. After being exposed to high temperature, the bonding performance of the planted bars decreased, and the slopes of the load-displacement curves were all slightly larger than those under normal temperature conditions. The strain of the inclined section satisfied the strain characteristics of the strut-and-tie model.

CLC number: U451.5 Document code: A Article ID: 1673-0836(2026)04-1316-10

References

【1】
【1】
 
 
Chinese Journal of Underground Space and Engineering
Pages 1316-1325

{{item.num}}

Comments on this article

Go to comment

< Back to all reports

Review Status: {{reviewData.commendedNum}} Commended , {{reviewData.revisionRequiredNum}} Revision Required , {{reviewData.notCommendedNum}} Not Commended Under Peer Review

Review Comment

Close
Close
Cite this article:
XU C, WANG Q, XU Q, et al. Experimental Research on Fire Performance of Hybrid Fiber Concrete Corbels for Flue Plate. Chinese Journal of Underground Space and Engineering, 2026, 22(4): 1316-1325. https://doi.org/10.20174/j.JUSE.2026.04.20

3

Views

0

Downloads

0

Crossref

0

Scopus

0

CSCD

Received: 07 October 2025
Published: 01 August 2026
© 2026 Chinese Journal of Underground Space and Engineering

This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).