AI Chat Paper
Note: Please note that the following content is generated by AMiner AI. SciOpen does not take any responsibility related to this content.
{{lang === 'zh_CN' ? '文章概述' : 'Summary'}}
{{lang === 'en_US' ? '中' : 'Eng'}}
Chat more with AI
PDF (5.9 MB)
Collect
Submit Manuscript AI Chat Paper
Show Outline
Outline
Show full outline
Hide outline
Outline
Show full outline
Hide outline
Open Access

Research on Control of Pollutants in Complex Underground Caverns Based on Required Air Volume Theory

Rongjun Xing1,2Yixian Liu1,2Pai Xu1,2( )Zhengpan Hu1,2Daiqiang Zhu1,2
State Key Laboratory of Mountain Bridge and Tunnel Engineering, Chongqing Jiaotong University, Chongqing 400074, P. R. China
School of Civil Engineering, Chongqing Jiaotong University, Chongqing 400074, P. R. China
Show Author Information

Abstract

The underground caverns has the advantages of safe concealment, environmental protection, and land saving. However, due to its enclosed space, pollutants are easily accumulated during construction. Consequently, improving the operation efficiency of the ventilation system and reducing energy consumption during the construction period are the keys to ensuring the safety of personnel and the normal operation of equipment. Taking an underground cavern project as the object, a theoretical calculation is used to determine the frequency conversion control strategy of the cavern fan, and numerical simulation (Fluent) is used to analyze the concentration changes of benzene and dust pollutants in the underground cavern before and after frequency conversion under the pressure ventilation condition, the field environmental quality monitoring data are compared and validated. The results show that: the concentration of pollutants on the longitudinal section of each cavern before and after continuous ventilation frequency conversion increases gradually and then stabilizes. The gradual conservation of pollutant generation and emission rates, with pollutant concentrations at breathing height below the limit values, verifies the effectiveness of the variable frequency strategy. In the construction site, the ventilation dynamic control system is established to realize the variable air volume control. When the axial flow fan maintains an energy-saving rate of around 25% and the jet fan maintains an energy-saving rate of over 60%, the pollutant concentration in the cavern remains within the limit range. This not only ensures the safety of construction personnel but also reduces energy consumption. The study can provide reference for the ventilation frequency conversion design of multi-face construction in underground caverns.

CLC number: U459.3 Document code: A Article ID: 1673-0836(2026)02-0732-10

References

【1】
【1】
 
 
Chinese Journal of Underground Space and Engineering
Pages 732-741

{{item.num}}

Comments on this article

Go to comment

< Back to all reports

Review Status: {{reviewData.commendedNum}} Commended , {{reviewData.revisionRequiredNum}} Revision Required , {{reviewData.notCommendedNum}} Not Commended Under Peer Review

Review Comment

Close
Close
Cite this article:
Xing R, Liu Y, Xu P, et al. Research on Control of Pollutants in Complex Underground Caverns Based on Required Air Volume Theory. Chinese Journal of Underground Space and Engineering, 2026, 22(2): 732-741. https://doi.org/10.20174/j.JUSE.2026.02.35

141

Views

0

Downloads

0

Crossref

0

Scopus

0

CSCD

Received: 11 July 2025
Published: 01 April 2026
© 2026 Chinese Journal of Underground Space and Engineering

This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).