AI Chat Paper
Note: Please note that the following content is generated by AMiner AI. SciOpen does not take any responsibility related to this content.
{{lang === 'zh_CN' ? '文章概述' : 'Summary'}}
{{lang === 'en_US' ? '中' : 'Eng'}}
Chat more with AI
PDF (8.3 MB)
Collect
Submit Manuscript AI Chat Paper
Show Outline
Outline
Show full outline
Hide outline
Outline
Show full outline
Hide outline
Open Access

Damage Analysis of Utility Tunnel Crossing Ground Fissure under Dislocation of the Hanging Wall and Footwall

Zhongming Xiong1,2,3, Jiabin Zhang1,2, Xuan Chen1,2( ), Jiawei Liang2,3
School of Civil Engineering, Xi'an University of Architecture and Technology, Xi'an 710055, P. R. China
Key Lab of Structural Engineering and Earthquake Resistance of the Ministry of Education, Xi'an University of Architecture and Technology, Xi'an 710055, P. R. China
XAUAT UniSA An De College, Xi'an University of Architecture and Technology, Xi'an 710311, P. R. China
Show Author Information

Abstract

In cities with dense ground fissure distributions, linear infrastructures like underground utility tunnel UUT) inevitably intersect with ground fissures. The vertical displacement between the hanging wall and footwall poses a significant threat to the safety of UUT in ground fissure site. For this reason, taking the UUT in Xi'an Happiness Forest Belt as the prototype structure, 3D finite element models that considered the soil-structure interaction were developed. The strain distribution, damage characteristics of the UUT, and the stress variations in the site soil under different dislocation magnitudes were analyzed. In addition, a damage index was introduced to establish the classification criteria DS0-DS3) for the safety evaluation of the UUT in order to assess the structural damage. The results indicate that: The tensile damage areas in the UUT are concentrated in the upper level compartment of footwall, the wall at the fissure location, and the lower level compartment of hanging wall; the compressive damage areas are concentrated in the wall at the fissure location; the main damage in the UUT is primarily controlled by tensile damage; the weak areas of the UUT are the bottom slab of the lower level large compartment in hanging wall, the side wall of the lower level large compartment at the fissure location, and the top slab of the upper level large compartment in footwall. When the vertical displacement reaches 300 mm, the plastic zone of the upper soil of the hanging wall UUT develops upwards and runs through the soil. Most of the damaged areas of the UUT reach DS3, causing large-scale concrete peeling and structure failure.

CLC number: TU435 Document code: A Article ID: 1673-0836(2025)06-2180-12

References

【1】
【1】
 
 
Chinese Journal of Underground Space and Engineering
Pages 2180-2191

{{item.num}}

Comments on this article

Go to comment

< Back to all reports

Review Status: {{reviewData.commendedNum}} Commended , {{reviewData.revisionRequiredNum}} Revision Required , {{reviewData.notCommendedNum}} Not Commended Under Peer Review

Review Comment

Close
Close
Cite this article:
Xiong Z, Zhang J, Chen X, et al. Damage Analysis of Utility Tunnel Crossing Ground Fissure under Dislocation of the Hanging Wall and Footwall. Chinese Journal of Underground Space and Engineering, 2025, 21(6): 2180-2191. https://doi.org/10.20174/j.JUSE.2025.06.33

368

Views

1

Downloads

0

Crossref

0

Scopus

0

CSCD

Received: 12 February 2025
Published: 01 December 2025
© 2025 Chinese Journal of Underground Space and Engineering

This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).