Study on Unidirectional Freezing Test and Numerical Simulation of Sandy Loam in Tianjin Area

Shoujie Wang1Tielun Ren2Jianwen Ding1( )Xueyang Jiao2Xueyuan Liu2
School of Transportation, Southeast University, Nanjing 211189, P. R. China
China Construction Eighth Engineering Division Rail Transit Construction Co., Ltd., Nanjing 210023, P. R. China
Show Author Information

Abstract

A closed-system unidirectional freezing experiment is conducted on the sandy silt found at the entrance and exit portal of the shield tunnel in Tianjin Metro. The test aims to investigate the temperature variation and frost heave deformation characteristics of frozen specimens under different freezing temperatures and moisture contents. Additionally, a numerical simulation of the unidirectional freezing process of sandy silt is performed using ANSYS finite element software. The test results indicate that: The higher initial moisture content in the soil, the longer duration of the stable freezing stage, and the initial freezing temperature of sandy silt increase with the increase of soil moisture content. Under the closed unidirectional freezing condition, the frost heave of the soil significantly grows with the increase of moisture content, while the influence of lower freezing temperatures on the final frost heave is relatively small. The simulated temperature variation trend corresponds well with the laboratory test results, except for an obvious mutation from the stable freezing stage to the slow cooling stage. As the freezing time progresses, the vertical frost heave increases at different depths within the soil. A more significant vertical displacement can be observed closer to the upper surface soil layer. After freezing for 500 minutes, the vertical frost heave displacement at different positions of the soil is linearly related to its depth.

CLC number: TU472.9 Document code: A Article ID: 1673-0836(2025)05-1636-10

References

【1】
【1】
 
 
Chinese Journal of Underground Space and Engineering
Pages 1636-1645

{{item.num}}

Comments on this article

Go to comment

< Back to all reports

Review Status: {{reviewData.commendedNum}} Commended , {{reviewData.revisionRequiredNum}} Revision Required , {{reviewData.notCommendedNum}} Not Commended Under Peer Review

Review Comment

Close
Close
Cite this article:
Wang S, Ren T, Ding J, et al. Study on Unidirectional Freezing Test and Numerical Simulation of Sandy Loam in Tianjin Area. Chinese Journal of Underground Space and Engineering, 2025, 21(5): 1636-1645. https://doi.org/10.20174/j.JUSE.2025.05.18

521

Views

1

Downloads

0

Crossref

0

Scopus

0

CSCD

Received: 16 February 2025
Published: 01 October 2025
© 2025 Chinese Journal of Underground Space and Engineering

This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).