AI Chat Paper
Note: Please note that the following content is generated by AMiner AI. SciOpen does not take any responsibility related to this content.
{{lang === 'zh_CN' ? '文章概述' : 'Summary'}}
{{lang === 'en_US' ? '中' : 'Eng'}}
Chat more with AI
PDF (3.3 MB)
Collect
Submit Manuscript AI Chat Paper
Show Outline
Outline
Show full outline
Hide outline
Outline
Show full outline
Hide outline
Open Access

Model Test of Static Drilling and Implanted Energy Pile Considering the Influence of Groundwater

Guangxing Cao1,2, Yuebao Deng1,2( ), Shuaijiong Chen1,2, Rihong Zhang3
Coastal Area Urban Rail Transit Collaborative Innovation Center, Ningbo University, Ningbo, Zhejiang 315211, P. R. China
Ningbo Key Laboratory of Thermal Underground Structure, Ningbo, Zhejiang 315211, P. R. China
Ningbo Zhongchun Hi-tech Co., LTD., Ningbo, Zhejiang 315145, P. R. China
Show Author Information

Abstract

In order to study the influence of groundwater flow on the bearing characteristics of static drilling deep-rooted energy pile in coastal area, a model test system of static drilling deep-rooted energy pile in 1.2 m thick soft clay interlaced with sand model ground was designed, so as to test and analyze the temperature, pore pressure, displacement and stress of pile-soil system with or without water flow. The results showed that groundwater flow reduced the temperature variation of pile, ranging from 6.39% to 34.15%. The temperature change of the downstream soil is obviously higher than that of the upstream soil, which is beneficial to reduce the thermal and cold accumulation effect of the soil around the pile. The water flow approximately reduces the hot pore pressure by 11% and the negative pressure by 20% in the surrounding soil, and the cumulative settlement of pile top is approximately reduced by 1/3. The tension stress of pile body caused by temperature is also reduced when groundwater flows. With the increase of load, the influence of water flow on friction decreases. Under the condition of underground flow, the maximum negative friction decreases under the rising and cooling conditions, which is conducive to the long-term work of static drilling of energy pile.

CLC number: TU473 Document code: A Article ID: 1673-0836(2025)01-0150-09

References

【1】
【1】
 
 
Chinese Journal of Underground Space and Engineering
Pages 150-158

{{item.num}}

Comments on this article

Go to comment

< Back to all reports

Review Status: {{reviewData.commendedNum}} Commended , {{reviewData.revisionRequiredNum}} Revision Required , {{reviewData.notCommendedNum}} Not Commended Under Peer Review

Review Comment

Close
Close
Cite this article:
Cao G, Deng Y, Chen S, et al. Model Test of Static Drilling and Implanted Energy Pile Considering the Influence of Groundwater. Chinese Journal of Underground Space and Engineering, 2025, 21(1): 150-158. https://doi.org/10.20174/j.JUSE.2025.01.17

433

Views

4

Downloads

0

Crossref

0

Scopus

0

CSCD

Received: 02 June 2024
Published: 01 February 2025
© 2025 Chinese Journal of Underground Space and Engineering

This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).