AI Chat Paper
Note: Please note that the following content is generated by AMiner AI. SciOpen does not take any responsibility related to this content.
{{lang === 'zh_CN' ? '文章概述' : 'Summary'}}
{{lang === 'en_US' ? '中' : 'Eng'}}
Chat more with AI
PDF (2 MB)
Collect
Submit Manuscript AI Chat Paper
Show Outline
Outline
Show full outline
Hide outline
Outline
Show full outline
Hide outline
Open Access

Safety Analysis Method for Steel Fiber Sprayed Concrete Structures

Wenzheng Wang1,2, Mingnian Wang1,2, Dagang Liu1,2( ), Zhilong Wang1,2, Jia Luo3,4
School of Civil Engineering, Southwest Jiaotong University, Chengdu 610031, P. R. China
Key Laboratory of Transportation Tunnel Engineering, Southwest Jiaotong University, Chengdu 610031, P. R. China
Sichuan University Jinjiang College, Meishan, Sichuan 620860, P. R. China
Network and Data Security Key Laboratory of Sichuan Province, University of Electronic Science and Technology of China, Chengdu 610054, P. R. China
Show Author Information

Abstract

As a new type of material for tunnel shotcrete support, steel fiber shotcrete has better tensile, crack resistance, and durability. To study its impact on bearing capacity and cracking when used for tunnel support, a safety analysis method for steel fiber shotcrete structures was established. This analysis method detects whether the steel fiber sprayed concrete component cracks under load based on the size of the steel fiber sprayed concrete component. If it does not crack, the component size is reasonable; If cracking occurs, it is necessary to calculate the actual crack width to determine whether it meets the requirements of safety regulations. According to the analysis process, engineering verification was conducted on three types of support types of steel fiber shotcrete for Class Ⅲ surrounding rock, namely Type Ⅰ, Type Ⅱ, and Class Ⅳ surrounding rock. The results showed that the thicker the steel fiber shotcrete for the same level of surrounding rock, the less likely it is to crack, and the higher its safety. The greater the load on different levels of the surrounding rock, the easier it is for steel fiber sprayed concrete of the same thickness to crack and the wider the crack width after cracking. At the same time, the theoretical calculation results are basically consistent with the on-site test results, verifying the practicality and effectiveness of the safety analysis method for steel fiber-sprayed concrete structures.

CLC number: U455.1 Document code: A Article ID: 1673-0836(2024)05-1676-10

References

【1】
【1】
 
 
Chinese Journal of Underground Space and Engineering
Pages 1676-1685

{{item.num}}

Comments on this article

Go to comment

< Back to all reports

Review Status: {{reviewData.commendedNum}} Commended , {{reviewData.revisionRequiredNum}} Revision Required , {{reviewData.notCommendedNum}} Not Commended Under Peer Review

Review Comment

Close
Close
Cite this article:
Wang W, Wang M, Liu D, et al. Safety Analysis Method for Steel Fiber Sprayed Concrete Structures. Chinese Journal of Underground Space and Engineering, 2024, 20(5): 1676-1685. https://doi.org/10.20174/j.JUSE.2024.05.24

321

Views

0

Downloads

0

Crossref

0

Scopus

0

CSCD

Received: 08 March 2024
Published: 01 October 2024
© 2024 Chinese Journal of Underground Space and Engineering

This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).