AI Chat Paper
Note: Please note that the following content is generated by AMiner AI. SciOpen does not take any responsibility related to this content.
{{lang === 'zh_CN' ? '文章概述' : 'Summary'}}
{{lang === 'en_US' ? '中' : 'Eng'}}
Chat more with AI
PDF (3 MB)
Collect
Submit Manuscript AI Chat Paper
Show Outline
Outline
Show full outline
Hide outline
Outline
Show full outline
Hide outline
Open Access

The Calculation Method of Anchor Rod Composite Anchoring Force Considering Transverse Constraint

Sifan Liu1, Wei Yuan1( ), Ruifeng Sun2, Haibin Li1,3, Anli Wang4
School of Civil Engineering, Shijiazhuang Tiedao University, Shijiazhuang 050043, P. R. China
China Railway 17th Bureau Group Urban Construction Co., Ltd, Zunyi, Guizhou 564512, P. R. China
Shenzhen Railway Investment&Construction Group Co.,Ltd, Shenzhen, Guangdong 518000
Guizhou Provincial Water Conservancy and Hydropower Survey and Design Institute Co., Ltd., Zunyi, Guizhou 550002, P. R. China
Show Author Information

Abstract

For the purpose of studying the calculation of composite anchor force of anchor rod and the influence of anchoring angle on the surface shear force of anchored structures under the condition that the shear direction and the anchor rod tend to be coplanar, FLAC3D finite element software is used for numerical simulation. Firstly, the numerical calculation models were established based on the solid elements and contact surface elements, and the parameters required for the numerical simulation are inverted by the physical experiment results. Secondly, fish language in FLAC3D was utilized to record the variation of shear force of structural plane with the increase of shear displacement during shearing. Finally, according to the geometric relationship in the mechanical model, the distribution function of the reaction force of the compressive side along the anchor rod was obtained. On the basis of the classical beam theory, the mechanical model was established, and the shear force calculation formula of the anchor rod at the structural surface was derived using the principle of minimum potential energy and the displacement variational method. The results demonstrate that the shear force on the anchorage structure surface first increases and then decreases with the increase of the anchoring angle. When the anchoring angle β≤ 90°, the “guide rail effect” of the anchor rod is more significant; When the anchoring angle β>90°, after shear deformation, the rocks are separated due to the deformation of the anchor rods.

CLC number: TU457 Document code: A Article ID: 1673-0836(2024)02-0378-09

References

【1】
【1】
 
 
Chinese Journal of Underground Space and Engineering
Pages 378-386

{{item.num}}

Comments on this article

Go to comment

< Back to all reports

Review Status: {{reviewData.commendedNum}} Commended , {{reviewData.revisionRequiredNum}} Revision Required , {{reviewData.notCommendedNum}} Not Commended Under Peer Review

Review Comment

Close
Close
Cite this article:
Liu S, Yuan W, Sun R, et al. The Calculation Method of Anchor Rod Composite Anchoring Force Considering Transverse Constraint. Chinese Journal of Underground Space and Engineering, 2024, 20(2): 378-386. https://doi.org/10.20174/j.JUSE.2024.02.04

500

Views

0

Downloads

0

Crossref

1

Scopus

1

CSCD

Received: 24 September 2023
Published: 01 April 2024
© 2024 Chinese Journal of Underground Space and Engineering

This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).