AI Chat Paper
Note: Please note that the following content is generated by AMiner AI. SciOpen does not take any responsibility related to this content.
{{lang === 'zh_CN' ? '文章概述' : 'Summary'}}
{{lang === 'en_US' ? '中' : 'Eng'}}
Chat more with AI
PDF (1.8 MB)
Collect
Submit Manuscript AI Chat Paper
Show Outline
Outline
Show full outline
Hide outline
Outline
Show full outline
Hide outline
Publishing Language: Chinese | Open Access

ECG abnormality detection algorithm and edge device design for on-device processing

Can GaoYubo DengKeni Qiu( )
Information Engineering College, Capital Normal University, Beijing 100048
Show Author Information

Abstract

Electrocardiogram (ECG) anomaly detection plays a critical role in the early diagnosis and timely treatment of patients with heart disease. This is particularly important for medical devices such as implantable cardioverter defibrillators (ICD), where it is essential to have detection algorithms that are not only highly accurate but also consume minimal power. Traditional detection methods often face challenges in achieving optimal performance on embedded devices with limited resources, which necessitates the exploration of new and innovative solutions. In this paper, we present the design of an ECG anomaly detection device that leverages the capabilities of artificial intelligence algorithms. For this purpose, the STM32F303K8T6 development board has been selected as the platform for model design and deployment. Additionally, we have implemented an evaluation system that thoroughly tests and assesses the performance of the deployed algorithms. The study undertakes a comprehensive comparison between deep learning algorithms and traditional machine learning algorithms, culminating in the proposal of a novel classification algorithm that combines hybrid features. Experimental results highlight that this algorithm not only demonstrates superior memory efficiency and reduced latency on resource-constrained ICD devices but also exhibits higher precision and robust generalization capabilities. This research provides a novel and effective solution for ECG anomaly detection, offering significant implications for the design of medical devices and the optimization of detection algorithms.

CLC number: TP391 Document code: A

References

【1】
【1】
 
 
Journal of Capital Normal University (Natural Science Edition)
Pages 53-59

{{item.num}}

Comments on this article

Go to comment

< Back to all reports

Review Status: {{reviewData.commendedNum}} Commended , {{reviewData.revisionRequiredNum}} Revision Required , {{reviewData.notCommendedNum}} Not Commended Under Peer Review

Review Comment

Close
Close
Cite this article:
Gao C, Deng Y, Qiu K. ECG abnormality detection algorithm and edge device design for on-device processing. Journal of Capital Normal University (Natural Science Edition), 2026, 47(4): 53-59. https://doi.org/10.19789/j.1004-9398.2026.04.006

2

Views

0

Downloads

0

Crossref

Received: 11 October 2024
Published: 20 August 2026
© The editorial department of Journal of Capital Normal University (Natural Science Edition) 2026.

This is an open access article under the CC BY-NC-ND 4.0 license (https://creativecommons.org/licenses/by-nc-nd/4.0/).