AI Chat Paper
Note: Please note that the following content is generated by AMiner AI. SciOpen does not take any responsibility related to this content.
{{lang === 'zh_CN' ? '文章概述' : 'Summary'}}
{{lang === 'en_US' ? '中' : 'Eng'}}
Chat more with AI
PDF (1.1 MB)
Collect
Submit Manuscript AI Chat Paper
Show Outline
Outline
Show full outline
Hide outline
Outline
Show full outline
Hide outline
Publishing Language: Chinese | Open Access

Method optimization for the determination of 11 phenolic compounds in ambient air based on HPLC technique

Haini LI1Ziyan CHEN2Kaitao CHEN2Xingru LI2( )
Wuxi Zero Carbon Environmental Management Co., Ltd, Wuxi Jiangsu 214000
Analysis and Testing Center, Department of Chemistry, Capital Normal University, Beijing 100048
Show Author Information

Abstract

In order to improve the precision of the detection of volatile phenols in ambient air and enhance the detection efficiency, the chromatographic conditions in the Determination of phenolic compounds in ambient air high performance liquid chromatography: HJ 638—2012 were optimized. In this paper, the column temperature was set at 40 ℃, 70.00% acetonitrile and 30.00% water which containing 0.10% formic acid was used as the initial mobile phase, the flow rate was 1.5 mL/min, the ultraviolet detection wavelength was 280 nm, and the injection volume was 10.0 μL, which achieved rapid and efficient separation of volatile phenolic compounds by high performance liquid chromatography(HPLC), and the method was used for the determination of 11 volatile phenols in ambient air in Beijing. Eleven volatile phenols in the ambient air of Beijing were determined by this method. The results showed that the volatile phenol contents in the range of 1.0 to 100.00 μg/mL had good linear correlation with the correlation coefficients>0.998 0. The method detection limits were all ≤6 492.0 ng/m3 with the relative standard deviations of 2.99% to 8.01% and the recoveries of 96.63% to 126.23% at the sample volume of 72 L. This method is in compliance with the industry requirements. This indicates that the precision and accuracy of the detection method established in this paper are high. In summary, this study presents a more efficient HPLC method with more significant separation effect, and it can meet the needs of monitoring volatile phenols in ambient air and exhaust gases.

References

【1】
【1】
 
 
Journal of Capital Normal University (Natural Science Edition)
Pages 64-70

{{item.num}}

Comments on this article

Go to comment

< Back to all reports

Review Status: {{reviewData.commendedNum}} Commended , {{reviewData.revisionRequiredNum}} Revision Required , {{reviewData.notCommendedNum}} Not Commended Under Peer Review

Review Comment

Close
Close
Cite this article:
LI H, CHEN Z, CHEN K, et al. Method optimization for the determination of 11 phenolic compounds in ambient air based on HPLC technique. Journal of Capital Normal University (Natural Science Edition), 2025, 46(4): 64-70. https://doi.org/10.19789/j.1004-9398.2025.04.009

257

Views

0

Downloads

0

Crossref

Received: 03 September 2024
Published: 01 August 2025
© The editorial department of Journal of Capital Normal University (Natural Science Edition) 2025.

This is an open access article under the CC BY-NC-ND 4.0 license (https://creativecommons.org/licenses/by-nc-nd/4.0/).