Comparison of DC breakdown characteristics and ionization capabilities of button-type metal diverter strips

Xi RAO1,2,3Xianchao MENG4Yadong FAN1,2,3Dongdong WANG5Xiaowei SU6Weihan ZHAO1,2,3Li CAI1,2,3Jinxin CAO1,2,3Jianguo WANG1,2,3Mi ZHOU1,2,3
State Key Laboratory of Power Grid Environmental Protection (Wuhan University), Wuhan 430072, China
Engineering Research Center of Ministry of Education for Lightning Protection and Grounding Technology, Wuhan 430072, China
School of Electrical Engineering and Automation Wuhan University, Wuhan 430072, China
Shanghai Institute of Satellite Engineering, Shanghai 200240, China
China Ship Development and Design Center, Wuhan 430064, China
China Railway First Survey and Design Institute Group Co., Ltd., Xi'an 710043, China
Show Author Information

Abstract

Objectives

To enhance the effectiveness of button-type metal diverter strips in ship-radome lightning protection, their ionization characteristics should be investigated under conditions simulating the vicinity of approaching lightning leaders.

Methods

We present the experimental results of DC breakdown voltage for button-type diverter strips with various button spacings, button shapes, and diverter strip lengths, for comparing their ionization capabilities. Accordingly, we performed electrostatic field distribution calculations for the corresponding strips.

Results

Our experimental results show that, with increasing diverter strip length, the breakdown voltage of diverter strip exhibits saturation. For a fixed diverter strip length, a larger spacing between metal buttons results in higher breakdown voltage. Moreover, the breakdown voltage of elliptical-button diverter strip is the lowest, roughly 77% of that of circular-button diverter strips. Furthermore, the breakdown voltage of rectangular-button diverter strips is about 86% of that of circular-button diverter strips. Our electrostatic field calculations suggest that the electric field intensity distribution of button-type diverter strip is relatively high at both ends and low in the middle, and that the smaller the spacing between buttons, the higher electric field strength at the gap near both ends. Compared with the circular-button and rectangular-button diverter strips, the electric field strength at both ends of the elliptical-button diverter strip is the highest. The electric field strength between the two ends of the diverter strip gap decreases nonlinearly with the increasing diverter strip length, thus explaining the variation in breakdown voltage observed in the experiments due to differences in button shapes and specifications.

Conclusions

Results provide a basis for the optimization of button-type metal shunt strips, thereby enhancing the lightning protection performance of radomes.

CLC number: U665.2 Document code: A

References

【1】
【1】
 
 
Chinese Journal of Ship Research
Pages 100-107

{{item.num}}

Comments on this article

Go to comment

< Back to all reports

Review Status: {{reviewData.commendedNum}} Commended , {{reviewData.revisionRequiredNum}} Revision Required , {{reviewData.notCommendedNum}} Not Commended Under Peer Review

Review Comment

Close
Close
Cite this article:
RAO X, MENG X, FAN Y, et al. Comparison of DC breakdown characteristics and ionization capabilities of button-type metal diverter strips. Chinese Journal of Ship Research, 2025, 20(3): 100-107. https://doi.org/10.19693/j.issn.1673-3185.03792

671

Views

29

Downloads

0

Crossref

0

Scopus

0

CSCD

Received: 23 February 2024
Revised: 08 April 2024
Published: 28 March 2025
© 2025 Chinese Journal of Ship Research.