AI Chat Paper
Note: Please note that the following content is generated by AMiner AI. SciOpen does not take any responsibility related to this content.
{{lang === 'zh_CN' ? '文章概述' : 'Summary'}}
{{lang === 'en_US' ? '中' : 'Eng'}}
Chat more with AI
PDF (11.7 MB)
Collect
Submit Manuscript AI Chat Paper
Show Outline
Outline
Show full outline
Hide outline
Outline
Show full outline
Hide outline
Research Article | Publishing Language: Chinese | Open Access

A study on fault ride-through strategies for mine DC power supply systems based on FBSM-MMC

Shengguang HAN1Junjie YAN1Yan GAO2Yanwen WANG2Zhixing KOU3( )
State Energy Group Baotu Mining Co., Ltd., Baotou Inner Mongolia 014016, China
School of Energy and Mining Engineering, China University of Mining and Technology-Beijing, Beijing 100083, China
Henan Pinggao Electric Co., Ltd., Pingdingshan Henan 467000, China
Show Author Information

Abstract

Direct current(DC)power supply system is a key technology for enhancing the power supply efficiency and safety of underground mining equipment due to its excellent voltage stability and little reactive power losses. However, its inherent low-impedance is likely to induce extremely rapid rise in short-circuit fault currents, posing a severe challenge to system protection. This study therefore proposes a valve-side, non-locking DC fault ride-through strategy based on a Modular Multi-Level Converter (MMC). Drawing on the mechanism of DC bipolar short-circuit faults, this strategy enables flexible and rapid switches of AC-DC modulation ratio within the MMC valves to generate a reverse voltage on the valve side that offsets the fault voltage. This could rapidly suppress and limit the short-circuit current, thus achieving superior system fault-ride-through and active current-limiting capabilities. RTLAB-based hardware-in-the-loop simulation verification demonstrates that this strategy could limit the DC short-circuit current to below 1.0 p.u. of the rated current within 2 ms after a fault occurs. This prevents dynamic and thermal damage to power supply cables and electrical equipment caused by inrush currents, ensuring the continuity of power supply during a fault. This study offers an economical and efficient solution for short-circuit protection of DC power supply systems in underground coal mine, thus providing theoretical and engineering references for the safe and reliable application of DC power supply technology in underground environments.

CLC number: TD411 Document code: A Article ID: 2096-2193(2026)03-0665-11

References

【1】
【1】
 
 
Journal of Mining Science and Technology
Pages 665-675

{{item.num}}

Comments on this article

Go to comment

< Back to all reports

Review Status: {{reviewData.commendedNum}} Commended , {{reviewData.revisionRequiredNum}} Revision Required , {{reviewData.notCommendedNum}} Not Commended Under Peer Review

Review Comment

Close
Close
Cite this article:
HAN S, YAN J, GAO Y, et al. A study on fault ride-through strategies for mine DC power supply systems based on FBSM-MMC. Journal of Mining Science and Technology, 2026, 11(3): 665-675. https://doi.org/10.19606/j.cnki.jmst.2026009

2

Views

0

Downloads

0

Crossref

0

Scopus

0

CSCD

Received: 27 May 2025
Revised: 30 September 2025
Published: 30 June 2026
© The Author(s) 2026

This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).