AI Chat Paper
Note: Please note that the following content is generated by AMiner AI. SciOpen does not take any responsibility related to this content.
{{lang === 'zh_CN' ? '文章概述' : 'Summary'}}
{{lang === 'en_US' ? '中' : 'Eng'}}
Chat more with AI
PDF (2.5 MB)
Collect
Submit Manuscript AI Chat Paper
Show Outline
Outline
Show full outline
Hide outline
Outline
Show full outline
Hide outline
Research Article | Publishing Language: Chinese | Open Access

Transient analysis of human electric shock current in frequency converter IT system based on Laplace transform

Guangzhong YUAN1( )Haisheng LIU2Zhijia YANG2Baojin SUN2Wei ZHANG2
State Power Investment Group Inner Mongolia Energy Co., Ltd., Hohhot Inner Mongolia 010050, China
Zhalute Flag Zahal Nur Coal Industry Co., Ltd., Tongliao Inner Mongolia 029123, China
Show Author Information

Abstract

In order to solve the difficulty in calculating the RMS value of human electlic shcck current caused by pulse modulated wave in case of electrocution accident in low voltage frequency converter IT power supply system of open-pit coal mine fire fighting, a transient analysis method based on Laplace transform is proposed. A transient analysis method of human elcctric shock current based on the Laplace transform is proposed to analyze the RMS value of the human electric shock current on the input side and output side of the frequency converter by establishing a piecewise linear model (PLM), and the distribution parameters on both sides of the frequency converter, the carrier frequency, the output frequency, and the load on the output side are investigated to characterize the influence of the electric shock current by constructing a MATLAB/Siumlink simulation model. The results show that the magnitude of human electric shock current is positively correlated with the capacitance distributed on each side of the frequency converter and the carrier frequency of the frequency converter under the different cases of distribution capacitance of 0.01~1.0 μF, output frequency of 30~60 Hz, and carrier frequency of 1~3 kHz, while it has little relationship with the output frequency of the frequency converter and the load connected to the output side. The simulation test results confirm the correctness of the theoretical analysis.

CLC number: TD411 Document code: A Article ID: 2096-2193(2025)04-0638-10

References

【1】
【1】
 
 
Journal of Mining Science and Technology
Pages 638-647

{{item.num}}

Comments on this article

Go to comment

< Back to all reports

Review Status: {{reviewData.commendedNum}} Commended , {{reviewData.revisionRequiredNum}} Revision Required , {{reviewData.notCommendedNum}} Not Commended Under Peer Review

Review Comment

Close
Close
Cite this article:
YUAN G, LIU H, YANG Z, et al. Transient analysis of human electric shock current in frequency converter IT system based on Laplace transform. Journal of Mining Science and Technology, 2025, 10(4): 638-647. https://doi.org/10.19606/j.cnki.jmst.2025029

519

Views

5

Downloads

0

Crossref

0

Scopus

0

CSCD

Received: 28 November 2024
Revised: 19 March 2025
Published: 31 August 2025
© The Author(s) 2025

This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).