AI Chat Paper
Note: Please note that the following content is generated by AMiner AI. SciOpen does not take any responsibility related to this content.
{{lang === 'zh_CN' ? '文章概述' : 'Summary'}}
{{lang === 'en_US' ? '中' : 'Eng'}}
Chat more with AI
PDF (826.6 KB)
Collect
Submit Manuscript AI Chat Paper
Show Outline
Outline
Show full outline
Hide outline
Outline
Show full outline
Hide outline
Clinical Research | Open Access

Cycloplegia is required for accurate refraction of young adults in epidemiologic studies

Xiao-Jie Feng1, Yuan-Zhen Liu1, Wen-Jia Cai1, Xiao-Qian Deng1, Ian G Morgan1,2, Ming-Guang He1,3,4,5, Xiao-Hu Ding1( )
State Key Laboratory of Ophthalmology, Zhongshan Ophthalmic Center, Sun Yat-sen University, Guangdong Provincial Key Laboratory of Ophthalmology and Visual Science, Guangdong Provincial Clinical Research Center for Ocular Diseases, Guangzhou 510060, Guangdong Province, China
Research School of Biology, College of Medicine, Biology and Environment, Australia National University, Canberra 2601, Australia
School of Optometry, The Hong Kong Polytechnic University, Kowloon, Hong Kong 999077, China
Research Centre for SHARP Vision (RCSV), The Hong Kong Polytechnic University, Kowloon, Hong Kong 999077, China
Centre for Eye and Vision Research (CEVR), 17W Hong Kong Science Park, Kowloon, Hong Kong 999077, China
Show Author Information

Abstract

AIM

To quantify the impact of the measurement of non-cycloplegic refraction on estimates of refraction and classification of refractive status in young adults.

METHODS

This cross-sectional analysis included 825 young adults (mean age 26.6±3.3y; 56.7% female) from the Guangzhou Twin Eye Study. All participants underwent both non-cycloplegic and cycloplegic autorefraction. Error in refraction was defined as the difference between cycloplegic and non-cycloplegic spherical equivalent refraction (SER).

RESULTS

Using a cut-off of -0.50 D for non-cycloplegic refraction to diagnose myopia, the prevalence of myopia was overestimated (90.2% vs 87.0%), resulting in the identification of 3.2% (26/825) pseudo-myopes. After increasing the threshold to -0.75 D, the overall prevalence (87.5%) was approximately equivalent to that with cycloplegic refraction, 9 of the 26 pseudo-myopes would have been re-classified correctly as emmetropes, but 13 genuine myopes would have been re-classified incorrectly as emmetropes. Lack of cycloplegia resulted in a significant myopic shift compared to cycloplegic refraction. Notably, 25.6% of participants exhibited a clinically significant myopia refractive shift of ≥0.50 D, and 5.7% demonstrated a large shift of ≥1.00 D.

CONCLUSION

At a threshold of -0.75 D, the calculated prevalence of myopia is close to that obtained with cycloplegic refraction. However, threshold adjustment does not solve the mis-classification problem, because while it will eliminate some pseudo-myopes, it will also eliminate some genuine myopes. Our study confirms that non-cycloplegic refraction leads to significant measurement errors in young adults, highlighting the necessity of cycloplegia for accurate epidemiologic assessment of myopia prevalence.

References

【1】
【1】
 
 
International Journal of Ophthalmology
Pages 2026-2030

{{item.num}}

Comments on this article

Go to comment

< Back to all reports

Review Status: {{reviewData.commendedNum}} Commended , {{reviewData.revisionRequiredNum}} Revision Required , {{reviewData.notCommendedNum}} Not Commended Under Peer Review

Review Comment

Close
Close
Cite this article:
Feng X-J, Liu Y-Z, Cai W-J, et al. Cycloplegia is required for accurate refraction of young adults in epidemiologic studies. International Journal of Ophthalmology, 2026, 19(10): 2026-2030. https://doi.org/10.18240/ijo.2026.10.18

7

Views

2

Downloads

0

Crossref

0

Web of Science

0

Scopus

0

CSCD

Received: 18 March 2026
Accepted: 08 June 2026
Published: 18 October 2026
© 2026 International Journal of Ophthalmology Press

This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).