AI Chat Paper
Note: Please note that the following content is generated by AMiner AI. SciOpen does not take any responsibility related to this content.
{{lang === 'zh_CN' ? '文章概述' : 'Summary'}}
{{lang === 'en_US' ? '中' : 'Eng'}}
Chat more with AI
PDF (715.2 KB)
Collect
Submit Manuscript AI Chat Paper
Show Outline
Outline
Show full outline
Hide outline
Outline
Show full outline
Hide outline
Clinical Research | Open Access

Visual and refractive evaluation of two diffractive trifocal intraocular lens platforms with distant and near dominant light energy distributions

Hyeck-Soo Son1, So Hyun Yu2, Kyungmin Koh2( ), Gerd U. Auffarth1, Grzegorz Łabuz1
Department of Ophthalmology, University of Heidelberg, David J. Apple International Laboratory for Ocular Pathology and International Vision Correction Research Centre, Heidelberg, BW 69120, Germany
Department of Ophthalmology, Kim’s Eye Hospital, Konyang University College of Medicine, Seoul 07301, Republic of Korea
Show Author Information

Abstract

AIM

To compare the visual, refractive, and optical performance of two diffractive trifocal intraocular lenses (IOLs) with analogous designs but different light distribution profiles.

METHODS

A total of 54 eyes from 48 patients undergoing cataract surgery received either the GemetricTM (GM; Hoya Surgical Optics, Singapore) or the GemetricTM Plus (GMP; Hoya Surgical Optics) IOLs. Preoperative demographics were comparable between the two groups. Generalized estimating equations (GEE) were utilized for statistical analysis to adjust for inter-eye correlations.

RESULTS

A total of 48 patients (54 eyes) were included in the analysis, of which 30 patients (33 eyes) received the GM IOL and 18 patients (21 eyes) the GMP IOL. The mean age was 59.6±6.1y (range: 48–72) in the GM group and 61.6±5.8y (range: 49–69) in the GMP group (P=0.339). At 3mo postoperatively, there were no statistically significant differences in uncorrected distance visual acuity (VA) and uncorrected near vision at 40 cm. However, the GM group showed statistically significantly better outcomes in corrected distance VA (P=0.003) and uncorrected intermediate VA at 66 cm (P=0.033). Conversely, uncorrected near VA at 33 cm was significantly superior in the GMP group (P=0.048). The objective assessment of optical quality showed improved distance and intermediate performance with the GM, while the GMP performed better at near, consistent with the patients’ measured visual outcomes.

CONCLUSION

Adjusting light distribution in otherwise identical trifocal IOLs results in distinct clinical and optical advantages, allowing surgeons to tailor IOL selection to patients’ specific visual demands.

References

【1】
【1】
 
 
International Journal of Ophthalmology
Pages 1971-1977

{{item.num}}

Comments on this article

Go to comment

< Back to all reports

Review Status: {{reviewData.commendedNum}} Commended , {{reviewData.revisionRequiredNum}} Revision Required , {{reviewData.notCommendedNum}} Not Commended Under Peer Review

Review Comment

Close
Close
Cite this article:
Son H-S, Yu SH, Koh K, et al. Visual and refractive evaluation of two diffractive trifocal intraocular lens platforms with distant and near dominant light energy distributions. International Journal of Ophthalmology, 2026, 19(10): 1971-1977. https://doi.org/10.18240/ijo.2026.10.11

7

Views

1

Downloads

0

Crossref

0

Web of Science

0

Scopus

0

CSCD

Received: 26 November 2025
Accepted: 24 June 2026
Published: 18 October 2026
© 2026 International Journal of Ophthalmology Press

This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).