AI Chat Paper
Note: Please note that the following content is generated by AMiner AI. SciOpen does not take any responsibility related to this content.
{{lang === 'zh_CN' ? '文章概述' : 'Summary'}}
{{lang === 'en_US' ? '中' : 'Eng'}}
Chat more with AI
PDF (3.1 MB)
Collect
Submit Manuscript AI Chat Paper
Show Outline
Outline
Show full outline
Hide outline
Outline
Show full outline
Hide outline
Clinical Research | Open Access

Enhanced predictability and axis precision of SMILE Pro, a retrospective analysis of myopic astigmatism correction

İlter İritaş1( )Ziya Burke2
Department of Ophthalmology, Faculty of Medicine, Başkent University, Istanbul 34662, Türkiye
Department of Ophthalmology, Faculty of Medicine, Medipol University, Istanbul 34214, Türkiye
Show Author Information

Abstract

AIM

To evaluate three-month visual and refractive outcomes after small incision lenticule extraction (SMILE) Pro with the VISUMAX 800 femtosecond laser for myopic astigmatism correction and to compare results with previously reported VISUMAX 800 and VisuMax 500 outcomes.

METHODS

Retrospective, observational clinical study. Records of 64 patients (128 eyes) who underwent SMILE Pro using the VISUMAX 800 laser (Carl Zeiss Meditec AG, Jena, Germany) between June and November 2024 were reviewed. Preoperative and 3-month postoperative data were analyzed in eyes with corrected distance visual acuity (CDVA) of 1.0 or better, including spherical equivalent (SE), refractive astigmatism, and vector analysis. Patients were classified into low (≤1.50 D) and high (>1.50 D) astigmatism subgroups.

RESULTS

The mean age of 64 patients (128 eyes) was 26.10±4.25y (19–36y). Attempted and achieved SE were strongly correlated (r=0.97, P<0.001). At 3mo, 36.7% and 87.5% of eyes were within ±0.50 and ±1.00 D of target refraction, respectively. Mean residual astigmatism was -0.56±0.27 D, lower in the low-astigmatism group (-0.39±0.23 D) than in the high group (-0.72±0.21 D; P<0.001). The mean absolute astigmatic angle of error was 4.47°±4.68°, with 97.6% ≤15°. No intraoperative or postoperative complications occurred.

CONCLUSION

SMILE Pro using the VISUMAX 800 femtosecond laser provides safe and predictable correction of myopic astigmatism with good axis alignment. However, the observed undercorrection in higher cylinders suggests that further optimization of astigmatic nomograms may improve refractive accuracy.

References

【1】
【1】
 
 
International Journal of Ophthalmology
Pages 1749-1756

{{item.num}}

Comments on this article

Go to comment

< Back to all reports

Review Status: {{reviewData.commendedNum}} Commended , {{reviewData.revisionRequiredNum}} Revision Required , {{reviewData.notCommendedNum}} Not Commended Under Peer Review

Review Comment

Close
Close
Cite this article:
İritaş İ, Burke Z. Enhanced predictability and axis precision of SMILE Pro, a retrospective analysis of myopic astigmatism correction. International Journal of Ophthalmology, 2026, 19(9): 1749-1756. https://doi.org/10.18240/ijo.2026.09.10

6

Views

1

Downloads

0

Crossref

0

Web of Science

0

Scopus

0

CSCD

Received: 04 February 2026
Accepted: 31 March 2026
Published: 18 September 2026
© 2026 International Journal of Ophthalmology Press

This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).