Review Article | Open Access

Intraocular pressure measurement in keratoconus: a narrative review

Rafael Vidal Merola1,2( )Sebastião Cronemberger2
Faculty of Medicine, Professor Antônio Carlos University Centre, UNIPAC, Juiz de Fora 36048-000, State of Minas Gerais, Brazil
Nassim Calixto Glaucoma Service of São Geraldo Eye Hospital, Clinic Hospital, Federal University of Minas Gerais, Belo Horizonte 30130-100, State of Minas Gerais, Brazil
Show Author Information

Abstract

Accurate measurement of intraocular pressure (IOP) is essential for the diagnosis and treatment of glaucoma. Keratoconus (KC) is an ectatic corneal disease, which evolves with progressive non-inflammatory thinning and is characterized by irregular astigmatism, and alteration of corneal biomechanics. There are many doubts regarding the best method to measure IOP in patients with KC, and, as far as we know, there are no manometric studies in patients with KC. It seems that IOP measurements made by Goldmann applanation tonometry (GAT) probably underestimate the real values in patients with KC. With the aim of obtaining more accurate measurements of IOP in KC, new devices were developed such as dynamic contour tonometry (DCT), ocular response analyzer (ORA) and corneal visualization scheimpflug technology (Corvis-ST). Possibly, DCT, corneal-compensated IOP (IOPcc)-ORA, and biomechanical corrected IOP (bIOP)-Corvis-ST can reduce some inaccuracies in IOP measurements related to thinning central corneal thickness and other biomechanical changes present in these patients. The different IOP measurement methods in KC are not interchangeable. Therefore, in KC we must always monitor IOP using the same device during follow-up. Furthermore, it is necessary to carefully study possible structural and functional changes that may occur in suspected cases of glaucoma.

References

【1】
【1】
 
 
International Journal of Ophthalmology
Pages 1608-1617

{{item.num}}

Comments on this article

Go to comment

< Back to all reports

Review Status: {{reviewData.commendedNum}} Commended , {{reviewData.revisionRequiredNum}} Revision Required , {{reviewData.notCommendedNum}} Not Commended Under Peer Review

Review Comment

Close
Close
Cite this article:
Merola RV, Cronemberger S. Intraocular pressure measurement in keratoconus: a narrative review. International Journal of Ophthalmology, 2026, 19(8): 1608-1617. https://doi.org/10.18240/ijo.2026.08.20

0

Views

0

Downloads

0

Crossref

0

Web of Science

0

Scopus

0

CSCD

Received: 13 August 2025
Accepted: 18 December 2025
Published: 18 August 2026
© 2026 International Journal of Ophthalmology Press

This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).