AI Chat Paper
Note: Please note that the following content is generated by AMiner AI. SciOpen does not take any responsibility related to this content.
{{lang === 'zh_CN' ? '文章概述' : 'Summary'}}
{{lang === 'en_US' ? '中' : 'Eng'}}
Chat more with AI
PDF (905.3 KB)
Collect
Submit Manuscript AI Chat Paper
Show Outline
Outline
Show full outline
Hide outline
Outline
Show full outline
Hide outline
Clinical Research | Open Access

Postoperative effective lens position and refraction changes with three different types of intraocular lens

Xi-Xia Ding1,2,3, Lin-Feng Xiang1,2,3, Wen-Tao Tong1,2,3, Dan-Dan Wang1,2,3, Hong-Fang Zhang1,2,3, Ping-Jun Chang1,2,3, Fu-Man Yang1,2,3, Yun-E Zhao1,2,3( )
Eye Hospital, Wenzhou Medical University, Wenzhou 325027, Zhejiang Province, China
Eye Hospital of Wenzhou Medical University (Hangzhou Campus), Hangzhou 310000, Zhejiang Province, China
National Clinical Research Center for Ocular Diseases, Wenzhou 325027, Zhejiang Province, China
Show Author Information

Abstract

AIM

To evaluate and compare alterations in the effective lens position (ELP) and refractive outcomes among three distinct intraocular lens (IOL) types.

METHODS

Patients with cataracts were enrolled and allocated to 3 groups: Group A (implanted with the SN6CWS), Group B (implanted with the MI60), and Group C (implanted with the Aspira-aA). ELP measurements were obtained with swept-source optical coherence tomography (SS-OCT) at 1d, 1wk, 1mo, and 3mo postoperatively. Subjective refraction assessments were conducted at 1wk, 1mo, and 3mo following surgery.

RESULTS

The study included 189 eyes of 150 cataract patients (66 males). There were 77 eyes in Group A, 55 eyes in Group B, and 57 eyes in Group C. The root mean square of the ELP (ELPRMS) within the initial 3mo was significantly lower for Group A than for Groups B and C. Refractive changes within Group A were not significant across the time points of 1wk, 1mo, and 3mo. Conversely, both Group B and Group C demonstrated statistically significant shifts toward hyperopia from 1wk to 3mo postsurgery.

CONCLUSION

Among the three IOLs examined, the SN6CWS IOL showes the greatest stability during the first 3mo postoperatively. Between 1wk and 3mo after surgery, notable hyperopic shifts are evident in eyes implanted with the MI60 and Aspira-aA IOLs, whereas refractive outcomes remain relatively constant in eyes implanted with SN6CWS IOLs.

References

【1】
【1】
 
 
International Journal of Ophthalmology
Pages 260-265

{{item.num}}

Comments on this article

Go to comment

< Back to all reports

Review Status: {{reviewData.commendedNum}} Commended , {{reviewData.revisionRequiredNum}} Revision Required , {{reviewData.notCommendedNum}} Not Commended Under Peer Review

Review Comment

Close
Close
Cite this article:
Ding X-X, Xiang L-F, Tong W-T, et al. Postoperative effective lens position and refraction changes with three different types of intraocular lens. International Journal of Ophthalmology, 2026, 19(2): 260-265. https://doi.org/10.18240/ijo.2026.02.07

1257

Views

71

Downloads

2

Crossref

2

Web of Science

2

Scopus

0

CSCD

Received: 28 February 2025
Accepted: 19 October 2025
Published: 18 February 2026
© 2026 International Journal of Ophthalmology Press

This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).