AI Chat Paper
Note: Please note that the following content is generated by AMiner AI. SciOpen does not take any responsibility related to this content.
{{lang === 'zh_CN' ? '文章概述' : 'Summary'}}
{{lang === 'en_US' ? '中' : 'Eng'}}
Chat more with AI
PDF (507.9 KB)
Collect
Submit Manuscript AI Chat Paper
Show Outline
Outline
Show full outline
Hide outline
Outline
Show full outline
Hide outline
Clinical Research | Open Access

Comparison of tear film quantity parameters between keratoconus and normal eyes

Foroozan Narooie-Noori1,2, Masoud Khorrami-Nejad1,3( ), Nabaa Ayad1,2, Hesam Hashemian3
Optometry Department, School of Rehabilitation, Tehran University of Medical Sciences, Tehran 1968653111, Iran
Students’ Scientific Research Center, Tehran University of Medical Sciences, Tehran 1968653111, Iran
Translational Ophthalmology Research Center, Farabi Eye Hospital, Tehran University of Medical Sciences, Tehran 1416753955, Iran
Show Author Information

Abstract

AIM

To compare the tear film quantity and stability parameters in keratoconus (KCN) and normal eyes using test breakup time (TBUT), noninvasive TBUT (NITBUT), and Schirmer test.

METHODS

All participants (n=166), including patients with KCN and age-matched healthy individuals with normal corneas, were recruited from those referred to Farabi Eye Hospital, Iran, in 2023. To better account for genetic and environmental factors, the control group comprised healthy individuals who were relatives of KCN patients and had normal corneal topography. Tear quantity parameters were evaluated in the following order: NITBUT, TBUT, and Schirmer tests.

RESULTS

The mean age of cases in KCN (61.7% males) and normal (63.5% males) participants was 27.54±5.44y (range 19 to 38) and 27.52±5.63y (range 20 to 38), respectively (P=0.976). NIBUT, TBUT, and Schirmer’s tests were significantly lower in KCN group compared to normal controls (all P<0.001). The mean difference for NIBUT was -7.81s (P<0.001), and for TBUT was -7.61s (P<0.001). Schirmer test values were also significantly lower in the KCN group, with a mean difference of -5.61 mm compared to normal people (P<0.001).

CONCLUSION

Our findings demonstrate significant tear film impairment in KCN. The reductions in NIBUT, TBUT and Schirmer scores highlight an underlying tear film dysfunction in KCN that extends beyond the morphological changes of the cornea.

References

【1】
【1】
 
 
International Journal of Ophthalmology
Pages 42-47

{{item.num}}

Comments on this article

Go to comment

< Back to all reports

Review Status: {{reviewData.commendedNum}} Commended , {{reviewData.revisionRequiredNum}} Revision Required , {{reviewData.notCommendedNum}} Not Commended Under Peer Review

Review Comment

Close
Close
Cite this article:
Narooie-Noori F, Khorrami-Nejad M, Ayad N, et al. Comparison of tear film quantity parameters between keratoconus and normal eyes. International Journal of Ophthalmology, 2026, 19(1): 42-47. https://doi.org/10.18240/ijo.2026.01.05

889

Views

44

Downloads

1

Crossref

0

Web of Science

0

Scopus

0

CSCD

Received: 18 February 2025
Accepted: 15 May 2025
Published: 18 January 2026
© 2026 International Journal of Ophthalmology Press

This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).