AI Chat Paper
Note: Please note that the following content is generated by AMiner AI. SciOpen does not take any responsibility related to this content.
{{lang === 'zh_CN' ? '文章概述' : 'Summary'}}
{{lang === 'en_US' ? '中' : 'Eng'}}
Chat more with AI
PDF (793.2 KB)
Collect
Submit Manuscript AI Chat Paper
Show Outline
Outline
Show full outline
Hide outline
Outline
Show full outline
Hide outline
Clinical Research | Open Access

Comparison of visual acuity and optical quality between higher-order aspheric monofocal and standard introcular lenses

Andrea Janekova1,2,3( ), Martina Polachova1, David P. Piñero4( ), Pavel Studeny1
Department of Ophthalmology, University Hospital Královské Vinohrady and 3rd Faculty of Medicine, Charles University, Prague 10034, Czech Republic
Faculty of Medicine, Charles University Hradec Kralove, Hradec Kralove 50003, Czech Republic
Eye Center Prague, Prague 17000, Czech Republic
Department of Optics, Pharmacology and Anatomy, University of Alicante, Alicante 03690, Spain
Show Author Information

Abstract

AIM

To compare the 12-month outcomes of visual performance and patient satisfaction of a higher-order aspheric monofocal intraocular lens (IOL) and a conventional monofocal IOL.

METHODS

Prospective, randomized, comparative, double-blinded study including 22 patients who underwent bilateral cataract surgery with implantation of the Tecnis Eyhance ICB00 IOL in one eye (ICB00 group) and the Tecnis ZCB00 IOL in the fellow eye (ZCB00 group). Uncorrected distance (UDVA), corrected distance (CDVA), uncorrected intermediate (UIVA), distance-corrected intermediate (DCIVA), uncorrected near (UNVA), and distance-corrected near visual acuities (DCNVA) were evaluated during a 12-month follow-up. Contrast sensitivity, defocus curves, and reading text size were also evaluated. Patient satisfaction was assessed with a questionnaire at the 6-month postoperative visit.

RESULTS

Mean postoperative logMAR UDVA was 0.01±0.12 and -0.02±0.10 in ICB00 and ZCB00 groups, respectively (P=0.37). Mean logMAR UIVA was 0.32±0.19 and 0.45±0.16 in ICB00 and ZCB00 groups, respectively (P=0.010). Differences between groups in UNVA did not reach statistical significance (P=0.16). The intermediate reading acuity at 66 cm (P=0.02) and 80 cm (P=0.04) was significantly better in the ICB00 group. Postoperative contrast sensitivity results did not differ significantly between groups (P>0.05). Patients reported high overall satisfaction, with 62% of patients using spectacles for reading in everyday life.

CONCLUSION

The eyes of patients implanted with the enhanced monofocal IOL evaluated have significantly better visual acuity for intermediate distances with the same contrast sensitivity as a conventional monofocal IOL.

References

【1】
【1】
 
 
International Journal of Ophthalmology
Pages 598-605

{{item.num}}

Comments on this article

Go to comment

< Back to all reports

Review Status: {{reviewData.commendedNum}} Commended , {{reviewData.revisionRequiredNum}} Revision Required , {{reviewData.notCommendedNum}} Not Commended Under Peer Review

Review Comment

Close
Close
Cite this article:
Janekova A, Polachova M, Piñero DP, et al. Comparison of visual acuity and optical quality between higher-order aspheric monofocal and standard introcular lenses. International Journal of Ophthalmology, 2025, 18(4): 598-605. https://doi.org/10.18240/ijo.2025.04.05

1333

Views

96

Downloads

9

Crossref

9

Web of Science

10

Scopus

0

CSCD

Received: 24 February 2024
Accepted: 04 December 2024
Published: 18 April 2025
© 2025 International Journal of Ophthalmology Press

This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).