AI Chat Paper
Note: Please note that the following content is generated by AMiner AI. SciOpen does not take any responsibility related to this content.
{{lang === 'zh_CN' ? '文章概述' : 'Summary'}}
{{lang === 'en_US' ? '中' : 'Eng'}}
Chat more with AI
PDF (1.6 MB)
Collect
Submit Manuscript AI Chat Paper
Show Outline
Outline
Show full outline
Hide outline
Outline
Show full outline
Hide outline
Clinical Research | Open Access

Flapless one-knot suture: a novel surgical technique for transscleral fixation of C-loop intraocular lenses

Qing-Qing Long1, Bao-Jiang Li2( )
Department of Ophthalmology, Gongli Hospital of Shanghai Pudong New Area, Shanghai 200135, China
Department of Ophthalmology, Shanghai General Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai 200080, China
Show Author Information

Abstract

AIM

To describe a novel suture approach for transscleral fixation of C-loop intraocular lenses (IOL) and to compare the surgical outcomes with the four-haptics posterior chamber (PC)-IOL technique.

METHODS

We retrospectively analyzed 16 eyes of 16 patients who underwent transscleral fixation of C-loop PC-IOLs using a flapless one-knot suture technique, which were followed up for longer than 17mo. In this technique, the capsulorless IOL was suspended using a single suture for transscleral fixation of four feet. Then we compared its surgical outcomes and complications with the four-haptics PC-IOLs using the Student’s t test and Chi-square test.

RESULTS

Sixteen patients of 16 eyes with a mean age of 58.3±10.1y (42-76y) who received transscleral C-loop IOL implantation due to trauma, vitrectomy, or cataract surgery with inadequate capsule support showed improved visual acuity. The difference was not significant between two IOLs except the surgery time (P>0.05). The mean operation times of C-loop IOL surgery was 24.1±1.83min and 31.3±4.47min of the four-haptics PC-IOL method (P<0.0001). In the C-loop IOLs group, there was statistical difference between the preoperative and the postoperative UCVA (logMAR, 1.20±0.50 vs 0.57±0.32, P=0.0003). There was no statistical difference between the preoperative and the postoperative BCVA (logMAR, 0.66±0.46 vs 0.40±0.23, P=0.056). However, there was no statistically significant difference in postoperative UCVA and BCVA between the two IOLs (P>0.05). We did not detect any optic capture, IOL decentration or dislocation, suture exposed, or cystoid macular edema in patients underwent C-loop IOLs surgery.

CONCLUSION

The novel flapless one-knot suture technique for transscleral fixation of C-loop IOL is a simple, reliable, and stable technique.

References

【1】
【1】
 
 
International Journal of Ophthalmology
Pages 736-742

{{item.num}}

Comments on this article

Go to comment

< Back to all reports

Review Status: {{reviewData.commendedNum}} Commended , {{reviewData.revisionRequiredNum}} Revision Required , {{reviewData.notCommendedNum}} Not Commended Under Peer Review

Review Comment

Close
Close
Cite this article:
Long Q-Q, Li B-J. Flapless one-knot suture: a novel surgical technique for transscleral fixation of C-loop intraocular lenses. International Journal of Ophthalmology, 2023, 16(5): 736-742. https://doi.org/10.18240/ijo.2023.05.10

415

Views

36

Downloads

2

Crossref

1

Web of Science

1

Scopus

0

CSCD

Received: 28 November 2022
Accepted: 27 March 2023
Published: 18 May 2023
© 2023 International Journal of Ophthalmology Press

This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).