AI Chat Paper
Note: Please note that the following content is generated by AMiner AI. SciOpen does not take any responsibility related to this content.
{{lang === 'zh_CN' ? '文章概述' : 'Summary'}}
{{lang === 'en_US' ? '中' : 'Eng'}}
Chat more with AI
PDF (1.7 MB)
Collect
Submit Manuscript AI Chat Paper
Show Outline
Outline
Show full outline
Hide outline
Outline
Show full outline
Hide outline
Regular Paper | Open Access

Linearization of Power Flow Model for Asymmetrically Coupled Electrified Railway-grid Hybrid System

Qiao Zhang1, Zhigang Liu1, Shibin Gao1, Zhenzu Liu1, Xiangyu Meng1( ), Guinan Zhang2, Bing Lu1, Yanming Lu1
School of Electrical Engineering, Southwest Jiaotong University, Chengdu 611756, China
China Academy of Railway Sciences Group Co., Ltd., Beijing 100081, China
Show Author Information

Abstract

In mountainous regions where traction loads constitute a significant portion of a long-chain weak power grid (PG) with a high penetration of sustainable energy sources, the interaction between the traction power supply system and the PG becomes increasingly significant. The integrated power flow calculation (PFC) method and its linearized model are critically important for the PG-traction network (TN) joint planning. However, existing research on the port-load characteristics of EMUs and the connection-angle characteristics of traction transformers remains insufficient, and no effective methods for PFC or linearized PFC exist in systems that couple the PG to the traction network. To fill this gap, this paper proposes an integrated PFC model for the AT TN − PG coupled system and a corresponding linearized method. First, based on the phase relationships between the PG and the AT traction network, the node admittance matrix of the coupled system is constructed. Then, the inability of power injection equations to handle the EMU port load is resolved by merging the contact line node and the rail node. Subsequently, the integrated PFC equations for the coupled system are established. Next, a hybrid phase linear decoupled (HPLD) power flow model for the coupled system is developed by leveraging the phase correspondence between the PG and the TN and the phase angle differences across various nodes and branches. Numerical simulations conducted in a specific region demonstrate the necessity of an integrated PFC for the coupled system and validate both the accuracy and efficiency of the linearized model.

References

【1】
【1】
 
 
CSEE Journal of Power and Energy Systems
Pages 1791-1808

{{item.num}}

Comments on this article

Go to comment

< Back to all reports

Review Status: {{reviewData.commendedNum}} Commended , {{reviewData.revisionRequiredNum}} Revision Required , {{reviewData.notCommendedNum}} Not Commended Under Peer Review

Review Comment

Close
Close
Cite this article:
Zhang Q, Liu Z, Gao S, et al. Linearization of Power Flow Model for Asymmetrically Coupled Electrified Railway-grid Hybrid System. CSEE Journal of Power and Energy Systems, 2026, 12(4): 1791-1808. https://doi.org/10.17775/CSEEJPES.2025.10350

4

Views

0

Downloads

0

Crossref

0

Web of Science

0

Scopus

0

CSCD

Received: 22 December 2025
Revised: 01 February 2026
Accepted: 02 March 2026
Published: 14 May 2026
© 2025 CSEE.

This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).