Transient Stability Enhancement of Grid-forming Inverters with Controllable Frequency Deviation via Acceleration Power Control

Xu Wu1, Huafeng Xiao1( ), Cunwen Tang2, Wei Wang2, Ming Cheng1
Department of Electrical Engineering, Southeast University, Nanjing 210096, China
State Grid Electric Power Research Institute (NARI Group Corporation), Nanjing 211106, China
Show Author Information

Abstract

Promoted by the extensive integration of distributed power resources, grid-connected inverters are progressively expected to function as grid-forming units. This requires them to not only regulate grid voltage and frequency but also provide inertia to compensate for the decline in traditional synchronous generation. Current studies on grid-forming inverters (GFMIs) have primarily focused on small-signal stability. However, the transient stability during voltage sags has not been adequately addressed. In this paper, the transient stability of GFMI is analyzed with the phase portrait, and an acceleration power control scheme is first proposed, which effectively constrains frequency deviations during both fault occurrence and clearance processes without requiring the estimation of voltage sag depth or line impedance. Remarkably, the proposed method ensures maintained synchronization stability of GFMIs even under severe grid faults. Finally, a 500W experimental platform is constructed in our lab to verify the effectiveness of the transient stability enhancement method.

References

【1】
【1】
 
 
CSEE Journal of Power and Energy Systems
Pages 2007-2018

{{item.num}}

Comments on this article

Go to comment

< Back to all reports

Review Status: {{reviewData.commendedNum}} Commended , {{reviewData.revisionRequiredNum}} Revision Required , {{reviewData.notCommendedNum}} Not Commended Under Peer Review

Review Comment

Close
Close
Cite this article:
Wu X, Xiao H, Tang C, et al. Transient Stability Enhancement of Grid-forming Inverters with Controllable Frequency Deviation via Acceleration Power Control. CSEE Journal of Power and Energy Systems, 2026, 12(4): 2007-2018. https://doi.org/10.17775/CSEEJPES.2025.04940