AI Chat Paper
Note: Please note that the following content is generated by AMiner AI. SciOpen does not take any responsibility related to this content.
{{lang === 'zh_CN' ? '文章概述' : 'Summary'}}
{{lang === 'en_US' ? '中' : 'Eng'}}
Chat more with AI
PDF (2.7 MB)
Collect
Submit Manuscript AI Chat Paper
Show Outline
Outline
Show full outline
Hide outline
Outline
Show full outline
Hide outline
Regular Paper | Open Access

Enhanced Two-step Nearest Level Control with Enhanced Power Quality for Electric Ship System

Hui Hwang Goh1( ), Jiaru Sun2, Xue Liang2, Dongdong Zhang2, Wei Dai2, Shaojian Song2, Tonni Agustiono Kurniawan3, Kai Chen Goh4
School of Engineering, Taylor’s University Lakeside Campus, 47500 Subang Jaya, Selangor, Malaysia
School of Electrical Engineering, Guangxi University, Nanning 530004, China
College of the Environment and Ecology, Xiamen University, Fujian 361102, China
Department of Construction Management, Faculty of Construction Management and Business, University Tun Hussein Onn Malaysia, 86400 Parit Raja, Johor, Malaysia
Show Author Information

Abstract

The implementation of modular multilevel converters (MMC) in an electric ship to create a medium voltage direct current (MVDC) energy conversion system that is efficient, small, dependable, and easily scalable has garnered considerable interest. In this research, an improved two-step nearest level control (E-NLC) is presented for MMC with a three-level submodule (3L-SM) as the rectifier of the electric ship power generation units in order to ease the economical and reliable operation of MMCs in MVDC systems. To achieve DC fault-clearing capability, the use of MMC with 3L-SM minimizes the number of switching devices when compared to the regular MMC topology. The suggested E-NLC scheme aims to reduce total harmonic distortion (THD) and achieve the nearest zero common mode voltage (CMV). The output voltage vector of the three phases is tuned using eight candidate vectors capable of suppressing CMV rather than the nearest-level vector, and the rounding function is modified to improve harmonic performance by increasing the approximation between stepped and modulated waves. The generator-connected MMC with THD reduction and CMV elimination maximizes the mover's protection in the generating unit of the electric ship's MVDC system. Simulation and experiment results validate the efficacy of the suggested approach with respect to steady-state and dynamic-state performance.

References

【1】
【1】
 
 
CSEE Journal of Power and Energy Systems
Pages 1670-1680

{{item.num}}

Comments on this article

Go to comment

< Back to all reports

Review Status: {{reviewData.commendedNum}} Commended , {{reviewData.revisionRequiredNum}} Revision Required , {{reviewData.notCommendedNum}} Not Commended Under Peer Review

Review Comment

Close
Close
Cite this article:
Goh HH, Sun J, Liang X, et al. Enhanced Two-step Nearest Level Control with Enhanced Power Quality for Electric Ship System. CSEE Journal of Power and Energy Systems, 2025, 11(4): 1670-1680. https://doi.org/10.17775/CSEEJPES.2023.00740

696

Views

38

Downloads

1

Crossref

1

Web of Science

1

Scopus

0

CSCD

Received: 02 February 2023
Revised: 27 May 2023
Accepted: 13 July 2023
Published: 03 May 2024
© 2023 CSEE.

This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).