AI Chat Paper
Note: Please note that the following content is generated by AMiner AI. SciOpen does not take any responsibility related to this content.
{{lang === 'zh_CN' ? '文章概述' : 'Summary'}}
{{lang === 'en_US' ? '中' : 'Eng'}}
Chat more with AI
PDF (2.1 MB)
Collect
Submit Manuscript AI Chat Paper
Show Outline
Outline
Show full outline
Hide outline
Outline
Show full outline
Hide outline
Regular Paper | Open Access

Bi-level Optimal Configuration of Hybrid Shared Energy Storage Capacity in Wind Farms Considering Prediction Error

Yifan Bian1, Peng Lu2, Lirong Xie1( ), Jiahao Ye1, Lan Ma1, Jianbin Yang1
Engineering Research Center for Energy Generation & Grid of Ministry of Education, Xinjiang University, Urumqi 830017, China
State Key Laboratory of Power System and Generation Equipment Tsinghua University, Beijing 100084, China
Show Author Information

Abstract

In wind farms, hybrid energy storage (HES) can effectively mitigate the fluctuation and intermittency of wind power output and effectively compensate for the prediction errors of wind power. However, the high cost of HES has prevented its large-scale adoption. Inspired by the sharing economy, this paper introduces the concept of hybrid shared energy storage (HSES) in wind farms. A rolling optimization (RO) strategy is formulated to obtain the reference power curve of the HES, and a bi-level optimal configuration model of HSES is established to minimize the wind farm's daily operating cost and optimize the compensation's performance for the prediction errors. The upper-level model aims to obtain the optimal rental capacity of HSES, and the lower level is an energy trading mechanism to optimize the trading power of the wind farm in real time. The simulation results reveal the excellent performance and economy of the proposed HSES model for wind farms.

References

【1】
【1】
 
 
CSEE Journal of Power and Energy Systems
Pages 2308-2317

{{item.num}}

Comments on this article

Go to comment

< Back to all reports

Review Status: {{reviewData.commendedNum}} Commended , {{reviewData.revisionRequiredNum}} Revision Required , {{reviewData.notCommendedNum}} Not Commended Under Peer Review

Review Comment

Close
Close
Cite this article:
Bian Y, Lu P, Xie L, et al. Bi-level Optimal Configuration of Hybrid Shared Energy Storage Capacity in Wind Farms Considering Prediction Error. CSEE Journal of Power and Energy Systems, 2026, 12(5): 2308-2317. https://doi.org/10.17775/CSEEJPES.2022.08300

10

Views

0

Downloads

0

Crossref

0

Web of Science

0

Scopus

0

CSCD

Received: 22 November 2022
Revised: 14 February 2023
Accepted: 15 March 2023
Published: 03 May 2024
© 2022 CSEE.

This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).