AI Chat Paper
Note: Please note that the following content is generated by AMiner AI. SciOpen does not take any responsibility related to this content.
{{lang === 'zh_CN' ? '文章概述' : 'Summary'}}
{{lang === 'en_US' ? '中' : 'Eng'}}
Chat more with AI
PDF (6.6 MB)
Collect
Submit Manuscript AI Chat Paper
Show Outline
Outline
Show full outline
Hide outline
Outline
Show full outline
Hide outline
Regular Paper | Open Access

Evolutionary Characteristics of Interfacial Defects Inside Vehicle-mounted High-voltage Cable Termination for High-speed Trains

Dongli XinGuangning Wu( )Kui ChenKai LiuYunlong XieGuoqiang GaoSong XiaoYujing TangChuanming SunMu Lin
High Voltage Lab, Southwest Jiaotong University, Chengdu 611756, China
Show Author Information

Abstract

Partial discharge caused by interfacial defects of cable terminations is an important factor affecting insulating performance, which will seriously threaten operational safety of high-speed trains by causing a breakdown fault of vehicle-mounted cable terminations. Simulation combined with experimentation is adopted to study the evolution characteristic of interfacial defects inside cable termination for high-speed trains. A simulation model and test samples of high-voltage cable terminations with prefabricated air gap and carbon trace defects are constructed. Results show that maximum field strength (MFS) at the defect is always located at the end of it. Evolution of the defects can be significantly divided into three stages based on the variation law of field strength and characteristics of partial discharge. A new feature of stage Ⅲ is that volume of discharge in the third quadrant is significantly higher than in the first quadrant. PDEV in this stage is 51.41% lower than that of the defect-free cable termination and lower than operating voltage. Therefore, stage Ⅲ is critical for detection of insulation state. Findings of the new characteristics and conclusions of the study provide strong support for improving operation and maintenance techniques of vehicle-mounted cable terminations.

References

【1】
【1】
 
 
CSEE Journal of Power and Energy Systems
Pages 1072-1085

{{item.num}}

Comments on this article

Go to comment

< Back to all reports

Review Status: {{reviewData.commendedNum}} Commended , {{reviewData.revisionRequiredNum}} Revision Required , {{reviewData.notCommendedNum}} Not Commended Under Peer Review

Review Comment

Close
Close
Cite this article:
Xin D, Wu G, Chen K, et al. Evolutionary Characteristics of Interfacial Defects Inside Vehicle-mounted High-voltage Cable Termination for High-speed Trains. CSEE Journal of Power and Energy Systems, 2026, 12(2): 1072-1085. https://doi.org/10.17775/CSEEJPES.2022.07910

75

Views

2

Downloads

1

Crossref

0

Web of Science

10

Scopus

0

CSCD

Received: 11 November 2022
Revised: 20 December 2022
Accepted: 29 December 2022
Published: 23 March 2023
© 2022 CSEE.

This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).