Regular Paper | Open Access

Stability Analysis for Direct-drive Wind Farm Transmitted via Flexible DC System Based on Dynamic Energy

Jing Ma, Ningsai Su, Yaqi Shen( )
State Key Laboratory of Alternate Electrical Power System with Renewable Energy Sources, North China Electric Power University, Beijing 102206, China
Show Author Information

Abstract

When direct-drive wind farms are transmitted via flexible DC systems, the interaction between different wind farms, flexible DC converters and multiple equipment often results in sub-synchronous oscillations. Concerning this problem, this paper considers the interaction between the direct-drive wind farm and flexible DC converter station and builds the dynamic energy model of the interconnected system. According to the source of energy, the dynamic energy in the system is decomposed into four parts: the PMSG (permanent magnet synchronous generator) induction energy, the inter-generator interaction energy, the flexible DC induction energy and the generator-grid interaction energy. These four components characterize the respective contributions of the wind farm’s inherent damping, the flexible DC system’s inherent damping, inter-generator interaction, and generator-grid interaction to the system’s overall stability. Then, based on the dynamic energy model of the system, the effects of PMSG integration distance, PMSG operation status, and flexible DC operation status on the stability level of the system are analyzed quantitatively. Finally, a model of a direct-drive wind farm transmitted via a flexible DC system is built in MATLAB/SIMULINK for simulation tests. The results verify that the interaction energy between the flexible DC converter station and PMSG and the interaction energy between the PMSGs with forced oscillation are the key factors that induce the oscillation.

References

【1】
【1】
 
 
CSEE Journal of Power and Energy Systems
Pages 2352-2366

{{item.num}}

Comments on this article

Go to comment

< Back to all reports

Review Status: {{reviewData.commendedNum}} Commended , {{reviewData.revisionRequiredNum}} Revision Required , {{reviewData.notCommendedNum}} Not Commended Under Peer Review

Review Comment

Close
Close
Cite this article:
Ma J, Su N, Shen Y. Stability Analysis for Direct-drive Wind Farm Transmitted via Flexible DC System Based on Dynamic Energy. CSEE Journal of Power and Energy Systems, 2026, 12(5): 2352-2366. https://doi.org/10.17775/CSEEJPES.2022.07150

14

Views

0

Downloads

0

Crossref

0

Web of Science

0

Scopus

0

CSCD

Received: 20 October 2022
Revised: 19 December 2022
Accepted: 16 February 2023
Published: 14 February 2024
© 2022 CSEE.

This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).