Regular Paper | Open Access

Improved Area-minimum Control Using Zero-sequence Components and Current Deviation Term

Juanjuan Wang1, Zhenxiao Yu1, Qiumei Wu2, Zhaoxin Wen3, Yuekun Liu1, Chuang Fu4( )
School of Electric Power Engineering, South China University of Technology, Guangzhou 510641, China
Guangzhou Power Supply Bureau, Guangdong Power Grid Company, Ltd., Guangzhou 510620, China
Power Dispatch Control Center of Yunnan Power Grid Co., Ltd., Kunming 650000, China
Electric Power Research Institute, China Southern Power Grid, Guangzhou 510663, China
Show Author Information

Abstract

In the synchronous firing control system of the line commutated converter (LCC) HVDC project, the Area-Minimum (AMIN) control is responsible for the real-time calculation of the commutation margin of each converter valve. Assume the AMIN control identifies a converter valve's commutation margin falling below the minimum threshold under AC fault conditions. In that case, the converter valve will be fired immediately to prevent commutation failure. However, the existing AMIN control faces several issues such as slow response time, inaccurate calculations, and a negative impedance characteristic that can negatively impact the steady operation of the HVDC project. Therefore, this paper proposes an improved AMIN control using zero-sequence components and a current deviation term that provides quick and accurate calculations of the commutation margin by utilizing the zero-sequence component of three-phase voltages and considering the DC current changes during commutation. Additionally, employing the current deviation term helps to enhance the performance of the LCC-HVDC's control system. Our simulations show that the proposed improved AMIN control significantly enhances the first commutation failure immunity and lowers the probability of subsequent commutation failures, thereby facilitating the restoration of the LCC-HVDC project.

References

【1】
【1】
 
 
CSEE Journal of Power and Energy Systems
Pages 2489-2501

{{item.num}}

Comments on this article

Go to comment

< Back to all reports

Review Status: {{reviewData.commendedNum}} Commended , {{reviewData.revisionRequiredNum}} Revision Required , {{reviewData.notCommendedNum}} Not Commended Under Peer Review

Review Comment

Close
Close
Cite this article:
Wang J, Yu Z, Wu Q, et al. Improved Area-minimum Control Using Zero-sequence Components and Current Deviation Term. CSEE Journal of Power and Energy Systems, 2026, 12(5): 2489-2501. https://doi.org/10.17775/CSEEJPES.2022.07120

24

Views

0

Downloads

0

Crossref

2

Web of Science

2

Scopus

0

CSCD

Received: 13 March 2023
Revised: 08 June 2023
Accepted: 13 July 2023
Published: 03 May 2024
© 2022 CSEE.

This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).