Dynamic Energy Model and Sub-synchronous Oscillation Mechanism for Direct-drive Wind Farm Considering Interaction Between Generators

Jing Ma( ), Honglu Xu
State Key Laboratory of Alternate Electrical Power System with Renewable Energy Sources, North China Electric Power University, Beijing 102206, China
Show Author Information

Abstract

Considering the interaction between generators, the dynamic energy model of direct-drive wind farm is proposed, and the effect mechanism of energy interaction on sub-synchronous oscillation is revealed. First, the dynamic energy model of direct-drive wind farm containing the generator-grid interaction links, inter-generator coupling interaction links and inter-generator induction interaction links is constructed. These energy links reflect the energy interaction between the generator and the grid, and between the generators during oscillation. Then, the dissipation energy representing the damping characteristics is extracted. Thus, the contribution degree of each interaction is quantitatively evaluated. On this basis, the influences of the current loop parameters, PLL parameters, the integration distance and the reference value of active current on the stability level are revealed, and the effect mechanism of generator-grid interaction and inter-generator interaction on sub-synchronous oscillation is clarified. Finally, a model of direct-drive wind farm is built, and the simulations show that, the generator-grid interaction and inter-generator coupling interaction are the key factors that affect the energy distribution. As the proportional gain of current loop and phase-locked loop and integration distance change, the two interactions are mutually exclusive.

References

【1】
【1】
 
 
CSEE Journal of Power and Energy Systems
Pages 1926-1939

{{item.num}}

Comments on this article

Go to comment

< Back to all reports

Review Status: {{reviewData.commendedNum}} Commended , {{reviewData.revisionRequiredNum}} Revision Required , {{reviewData.notCommendedNum}} Not Commended Under Peer Review

Review Comment

Close
Close
Cite this article:
Ma J, Xu H. Dynamic Energy Model and Sub-synchronous Oscillation Mechanism for Direct-drive Wind Farm Considering Interaction Between Generators. CSEE Journal of Power and Energy Systems, 2026, 12(4): 1926-1939. https://doi.org/10.17775/CSEEJPES.2022.06750

1

Views

0

Downloads

0

Crossref

0

Web of Science

0

Scopus

0

CSCD

Received: 08 October 2022
Revised: 30 November 2022
Accepted: 13 January 2023
Published: 14 February 2024
© 2022 CSEE.

This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).