AI Chat Paper
Note: Please note that the following content is generated by AMiner AI. SciOpen does not take any responsibility related to this content.
{{lang === 'zh_CN' ? '文章概述' : 'Summary'}}
{{lang === 'en_US' ? '中' : 'Eng'}}
Chat more with AI
PDF (2 MB)
Collect
Submit Manuscript AI Chat Paper
Show Outline
Outline
Show full outline
Hide outline
Outline
Show full outline
Hide outline
Regular Paper | Open Access

Adaptive Staged Overcurrent Protection Using Pre-fault and Post-fault Thevenin Parameters

Shimin Xue, Yuexuan Li( ), Junting Zhang, Xu Zhang, Bin Li
School of Electrical and Information Engineering, Tianjin University, Tianjin 300072, China
Show Author Information

Abstract

This paper presents an adaptive staged overcurrent protection system based on predicted post-fault Thevenin equivalent parameters. The presented protection scheme can be used in a distribution system with more than one Inverter Interfaced Distribution Generators (IIDGs). To implement the protection system, equations of pre-fault and post-fault Thevenin equivalent parameters are obtained and relationship between them is revealed. Then protection’s stage Ⅰ and stage Ⅱ trip currents are calculated by an easy algorithm based on that relationship. What’s more, a sensitivity verification is applied to the Stage Ⅱ operating current, enabling both Stage Ⅰ and Stage Ⅱ to protect the entire line, similar to conventional overcurrent (OC) protection. To verify equations and ensure protection system working normally, a distribution system is built in PSCAD/EMTDC. Simulation and calculation results show that the sensitivity and the selectivity of the protection system satisfy the need of an OC protection.

References

【1】
【1】
 
 
CSEE Journal of Power and Energy Systems
Pages 2318-2327

{{item.num}}

Comments on this article

Go to comment

< Back to all reports

Review Status: {{reviewData.commendedNum}} Commended , {{reviewData.revisionRequiredNum}} Revision Required , {{reviewData.notCommendedNum}} Not Commended Under Peer Review

Review Comment

Close
Close
Cite this article:
Xue S, Li Y, Zhang J, et al. Adaptive Staged Overcurrent Protection Using Pre-fault and Post-fault Thevenin Parameters. CSEE Journal of Power and Energy Systems, 2026, 12(5): 2318-2327. https://doi.org/10.17775/CSEEJPES.2022.06440

11

Views

0

Downloads

0

Crossref

0

Web of Science

0

Scopus

0

CSCD

Received: 21 September 2022
Revised: 25 November 2022
Accepted: 29 December 2022
Published: 28 December 2023
© 2022 CSEE.

This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).