AI Chat Paper
Note: Please note that the following content is generated by AMiner AI. SciOpen does not take any responsibility related to this content.
{{lang === 'zh_CN' ? '文章概述' : 'Summary'}}
{{lang === 'en_US' ? '中' : 'Eng'}}
Chat more with AI
PDF (3 MB)
Collect
Submit Manuscript AI Chat Paper
Show Outline
Outline
Show full outline
Hide outline
Outline
Show full outline
Hide outline
Regular Paper | Open Access

Subsequent Commutation Failure Suppression Control for LCC-HVDC System Based on Fuzzy Clustering

Chunyi Guo1 ( ), Quan Ye1, Xiuyu Chen2, Chengyong Zhao1
North China Electric Power University, Beijing 102206, China
Electranix Corporation, Manitoba, Canada
Show Author Information

Abstract

Line-commutated converter-based high voltage direct current (LCC-HVDC) may experience subsequent commutation failure (SCF) following a first commutation failure (CF). The SCF could create a series of serious disturbances to the AC grid and DC system, which may lead to large power reduction or even system instability issues. To prevent its occurrence, this paper proposes an SCF suppression control strategy based on fuzzy clustering and identification approach. First of all, the similar dynamic behavior of DC side electrical quantities in different types of AC faults at the inverter side is revealed and validated by theoretical analysis and simulation. Then, transient response information of the selected DC side electrical quantities at the rectifier side is collected in an offline preset specific AC fault. To identify the inverter transient stage, a mapping relationship between the selected DC side electric quantities during the transient stages of the preset fault conditions is established by the fuzzy c-means (FCM) clustering algorithm. Finally, an approach to inhibit SCF by directly adjusting the firing angle at the rectifier side is proposed based on the mapping relationship. Simulation results show the proposed control method, which is realized by detecting the local DC-side electrical quantities at the rectifier side and quickly identifying the transient stage of the inverter, can effectively inhibit SCF by directly regulating the rectifier firing angle.

References

【1】
【1】
 
 
CSEE Journal of Power and Energy Systems
Pages 2415-2424

{{item.num}}

Comments on this article

Go to comment

< Back to all reports

Review Status: {{reviewData.commendedNum}} Commended , {{reviewData.revisionRequiredNum}} Revision Required , {{reviewData.notCommendedNum}} Not Commended Under Peer Review

Review Comment

Close
Close
Cite this article:
Guo C, Ye Q, Chen X, et al. Subsequent Commutation Failure Suppression Control for LCC-HVDC System Based on Fuzzy Clustering. CSEE Journal of Power and Energy Systems, 2026, 12(5): 2415-2424. https://doi.org/10.17775/CSEEJPES.2022.05740

11

Views

0

Downloads

0

Crossref

0

Web of Science

0

Scopus

0

CSCD

Received: 22 August 2022
Revised: 14 November 2022
Accepted: 08 February 2023
Published: 14 February 2024
© 2022 CSEE.

This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).