AI Chat Paper
Note: Please note that the following content is generated by AMiner AI. SciOpen does not take any responsibility related to this content.
{{lang === 'zh_CN' ? '文章概述' : 'Summary'}}
{{lang === 'en_US' ? '中' : 'Eng'}}
Chat more with AI
PDF (1.4 MB)
Collect
Submit Manuscript AI Chat Paper
Show Outline
Outline
Show full outline
Hide outline
Outline
Show full outline
Hide outline
Regular Paper | Open Access

DC-side Pole-to-ground Fault Current Calculation for Multi-terminal LCC-MMC Hybrid HVDC System

Zhen He1, Pingliang Zeng1( ), Yuanzhu Chang2, Lijun Hang1, Yanhua Liu3
School of Automation, Hangzhou Dianzi University, Hangzhou 310018, China
Polytechnique Montréal, affiliated with Université de Montréal, Québec, Canada
State Grid Hangzhou Power Supply Company, Hangzhou 310000, China
Show Author Information

Abstract

A multi-terminal hybrid high voltage direct current (HVDC) system integrating both line commutated converter (LCC) and modular multilevel converter (MMC) is becoming an emerging solution for long distance and bulk power transmission. To protect this system from short circuits, the pole-to-ground (PTG) fault current calculation is of vital importance. However, PTG fault analysis faces three major challenges: nonlinear characteristics introduced by LCC, asymmetry of PTG fault and inherent coupling between DC transmission lines. In this paper, in light of the nonlinear obstacle, DC characteristics of LCC and its specific nonlinear form are analyzed. Then, for system-level fault current calculation, a linear transient model is established for LCC with the piecewise linearization method. To address the asymmetry and coupling issues, a common- and differential-mode (CDM) transformation-based analysis method is proposed. By transforming the multi-terminal hybrid HVDC system into CDM networks, analytical expressions of PTG fault currents are presented in this paper. Analytical expression of PTG fault current reveals the underlying fault mechanism, and can be used to select proper fault protection equipment, the validity of which is fully verified by PSCAD/EMTDC simulation.

References

【1】
【1】
 
 
CSEE Journal of Power and Energy Systems
Pages 1975-1984

{{item.num}}

Comments on this article

Go to comment

< Back to all reports

Review Status: {{reviewData.commendedNum}} Commended , {{reviewData.revisionRequiredNum}} Revision Required , {{reviewData.notCommendedNum}} Not Commended Under Peer Review

Review Comment

Close
Close
Cite this article:
He Z, Zeng P, Chang Y, et al. DC-side Pole-to-ground Fault Current Calculation for Multi-terminal LCC-MMC Hybrid HVDC System. CSEE Journal of Power and Energy Systems, 2026, 12(4): 1975-1984. https://doi.org/10.17775/CSEEJPES.2022.04870

1

Views

0

Downloads

0

Crossref

0

Web of Science

0

Scopus

0

CSCD

Received: 20 July 2022
Revised: 04 November 2022
Accepted: 12 November 2022
Published: 03 March 2023
© 2022 CSEE.

This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).