Double-ended Fast Protection System Independent of LCC-VSC-MTDC in Boundary Components

Dahai Zhang ( ), Chuanjian Wu, Pinghao Ni, Jinghan He
School of Electrical Engineering, Beijing Jiaotong University, Beijing 100044, China
Show Author Information

Abstract

Hybrid DC transmission technology is used in new energy transmission due to its advantages of large capacity and long distances. Line-commutated converter-voltage source converter-multi-terminal DC (LCC-VSC-MTDC) is one of the more important development directions in future power grids. But the multi-terminal high voltage direct current system has problems of inconsistent boundary characteristics, inconsistent control, and fault response characteristics, which places higher requirements on the protection scheme. A protection scheme based on the undistorted factor is proposed to ensure the safe operation of the system. First, the inconsistent line mode voltage attenuation characteristics of different fault locations are used to construct the undistorted factor. Subsequently, the undistorted factor is used to identify fault. The advantage of this scheme is that it remains unaffected by boundary elements, control strategies, and distributed capacitance. Finally, the LCC-VSC-MTDC model verifies the correctness and superiority of the proposed protection scheme.

References

【1】
【1】
 
 
CSEE Journal of Power and Energy Systems
Pages 1544-1555

{{item.num}}

Comments on this article

Go to comment

< Back to all reports

Review Status: {{reviewData.commendedNum}} Commended , {{reviewData.revisionRequiredNum}} Revision Required , {{reviewData.notCommendedNum}} Not Commended Under Peer Review

Review Comment

Close
Close
Cite this article:
Zhang D, Wu C, Ni P, et al. Double-ended Fast Protection System Independent of LCC-VSC-MTDC in Boundary Components. CSEE Journal of Power and Energy Systems, 2025, 11(4): 1544-1555. https://doi.org/10.17775/CSEEJPES.2021.05810

645

Views

36

Downloads

2

Crossref

5

Web of Science

5

Scopus

0

CSCD

Received: 12 August 2021
Revised: 07 October 2021
Accepted: 04 December 2021
Published: 06 May 2022
© 2021 CSEE.

This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).